WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP
31
EN - Rev. 1.2
Remove the two hex screws completely in order to remove the inspection vent below the oven
(figure 5 e 6)
. Next
remove the counter plate which fastens the vent
(figure 7)
and vacuum any ash deposited inside
(figure 8)
.
Once cleaned, reassemble the inspection vent below the oven
(figures 9 and 10)
taking care to ensure the gasket
guarantees an adequate seal against flue gases.
WARNING: use suitable ash vacuum devices equipped with a fine mesh filter in order to prevent ash from being
blown into the room and to prevent damaging the vacuum cleaner. We do not recommend the use of normal
vacuum cleaners.
Deposits on the walls of the combustion chamber (if particularly resinous wood is burned) can be eliminated by running
the appliance at maximum for 30-40 minutes (in this case set the thermostat to 80
℃
) with thin dry wood.
Leave the fire to go out and then scrape the inside walls using a steel spatula. Do not use tools that can reduce the
thickness of the metal sheet of the boiler unit.