2. Ensure the accelerator pedal is not pressed and turn the ignition key “ON”; the
parking brake is automatically released.
3. Select the desired travelling direction (forward or backward)
4. RIDO: press switch (ON/OFF) to lower the brushes plate down until it lay on the
ground, in its end stop position (not adjustable).
HILO: operate the switch (progressive) to adjust the load of brushes on the ground,
possibly adjusting (+/- loaded) the position with respect to the floor.
5. Press the brush start switch on the control panel. The brush motor is ready to be
started. The brushes will only start turning when the operator starts pressing the speed
pedal,
6. Turn the knob on the panel to adjust solution water opening,
7. Press the vacuum turbine switch on to start the extraction system.
8. Adjust the machine speed, through the accelerator pedal, after setting the maximum
attainable speed, turn the speed control knob, located on the fuse panel.
NOTE: Brush rotation and solution flow are automatically interrupted when the operator
decides to stop the machine and no longer presses on the accelerator pedal. Brush
motion and flow automatically resume when the accelerator pedal is pressed again.
13.3. INTERRUPTION OF BRUSH MOTION AND WASHING
1. Press the switch that controls brush rotation on the control panel. The brush motor is
de-activated.
2. Lifting one's foot off the accelerator is also enough to stop brush rotation, the machine
stops and the brushes stop
3. Press the switch that controls complete brush plate lifting, it is
lifted in parking position. After 5 seconds the extraction motor is stopped. This delay is
to allow for complete emptying of the
recovered solution which is still present in the extraction pipe.
4. Brake until the machine stops.
5. Turn the ignition key “OFF” or get off the machine.
5. The parking brake is automatically engaged.
13.4. DOUBLE WASHING and SINGLE DRYING
Particularly dirty floors may not be sufficiently cleaned with one pass. In these cases
double brushing must be performed.
To perform double brushing and washing, carry out a first pass with the wiper lifted by
acting on the manual cam located on the side of the steering column, solution flow
activated and brushes lowered. In this way the solution is in contact with the floor while
the brushes work to reduce the layer of dirt. Leave a reasonable length of time elapse so
that the solution is sufficiently in contact with the floor. The length of time elapsed
between the