5.2.6.3.25.2 Matters needing attention
SET LOOP V has been set by the factory, non annual inspection or professional
personnel do not operate.
5.2.6.3.26 SET LOOP
5.2.6.3.26.1 Setting the Delay time and the Percentage that process frequency compare with
empty pipe. Once process frequency comes over the percentage, the output will
keep the last values (Mass Flow/Volume Flow/Density). If the process frequency
comes over the percentage & keeps over the delay time, the outputs drive to “0”.
5.2.6.3.26.2 Default: 1.0 s & 40%
5.2.6.3.27 Grd1
5.2.6.3.27.1 The threshold value 1 of flow changing slope.
5.2.6.3.27.2 Default: 0.015.
5.2.6.3.27.3 Matters needing attention
The Grd1 has been set by the factory, non annual inspection or professional
personnel do not operate.
5.2.6.3.28 Grd1Co
5.2.6.3.28.1 The adopted filter coefficient when flow change slope>Grd1 or frequency
variation>DoF.
5.2.6.3.28.2 Default: 1.000.
5.2.6.3.28.3 Matters needing attention
The Grd1C has been set by the factory, non annual inspection or professional
personnel do not operate.
5.2.6.3.29 Grd2
5.2.6.3.29.1 The threshold value 2 of flow change slope.
5.2.6.3.29.2 Default: 0.008.
5.2.6.3.29.3 Matters needing attention
The Grd2 has been set by the factory, non annual inspection or professional
personnel do not operate.
5.2.6.3.30 Grd2Co
5.2.6.3.30.1 The adopted filter coefficient when Grd1 >flow change slope>Grd2.
5.2.6.3.30.2 Default: 0.700.
5.2.6.3.30.3 Matters needing attention
The Grd2C has been set by the factory, non annual inspection or professional
personnel do not operate.
5.2.6.3.31 CoT
5.2.6.3.31.1 The adopted filter coefficient when flow change slope<Grd2, and phase
difference >DoS.
5.2.6.3.31.2 Default: 0.050.
5.2.6.3.31.3 Matters needing attention
The CoT has been set by the factory, non annual inspection or professional
personnel do not operate.
5.2.6.3.32 CoS
5.2.6.3.32.1 The adopted filter coefficient when flow change slope<Grd2, and phase difference
<DoS.