Instructions for use, installation and connection
22
Electric connection
Electric connection must be carried
out by qualified service personnel
only!
Wrong connection may permanently
damage parts of the appliance and render
your warranty void!
Mains voltage of the user (240 V) must be verified
with the measuring device!
•
Before attempting the connection, check
whether the voltage indicated on the rating plate
corresponds to the actual mains voltage.
•
Mains lead should be minimum 1.5 m long, to
enable access for servicing of the oven.
•
Earthing wire should be installed in such
manner to be the last one pulled out in case the
safety relief device of the mains lead should fail.
Connection
•
Using a screwdriver open the connector cover
at the rear of the appliance. Release two locks
located at either side of the connector bottom.
•
Mains lead must be led through the relief safety
device, protecting the mains lead cable from
disconnection.
•
Tighten the relief device securely and close the
connector cover.
Colour code
L1, L2, L3 = exterior live wires, usually coloured
black, black, brown.
N = neutral
The colour is usually blue.
Beware of the correct N-connection!
PE = earthing wire
The colour is green/yellow.