-32
-
english
francais
To return to the default parameter actuate the following
keys:
and
and
The input has to be made within 3 seconds.
Afterwards you can choose German, English or French as operation language.
This will be done with the key which now has the effect
of an arrow head key.
The choice is to be confirmed with the key .
With the which has now the effect of an arrow head
key a allows you to change from Sl- to the US-measuring units.
Confirm the choice with the key .
Sl-units are e.g. bar, kN etc.
When switching over to US-measuring units the common scales are e.g. psi or
am. to.
The next menu for the data input is immediately called.
The input is done by means of the two keys for the
input of the figures and selection command of the
next decimal place.
Please observe that each line after the input of the figures is finished by pressing
the key ; only then a jump to the next line follows.
1.2 Initializing
In industrial plants strong electromagnetic interferences acceeding the values published in the EN 50081 and EN 50082, may distort resp.
disturb results in digital electronic devices. This becomes apparent when unlikely measuring data is generated or when the unit does not reakt
on any input.
In this case you have the possibility to set the unit on the initial pre-set default parameters. However all your parameters you fed in before
such as calibration value, measuring units, current output of the pressure sensors and force sensors will then be deleted.
SPRACHE / LANGUAGE
Deutsch
Initialization
Version 2.1
* * * * * UNIT * * * *
SI
US
p
F
Prog
ENT
* * * Date input * * * *
* Day : 01
Month : 06
Year : 1999
* * * Time input * * * *
* hours : 13
minutes : 55
Prog
ENT
Prog
ENT
1.3 Date input and time