76
EN
Alarm
Possible cause
Suggested solution
Overheating of the smoke.
Reduce the pellet supply of
the screw motor.
Overheating in the hopper.
Reduce the pellet supply of
the screw motor.
Error at the temperature
control switch in the
hopper. Have the switch
replaced.
The hopper is empty.
Fill the hopper and start
the heater.
Problem with the thermal
element or poor contact
with the anode and
cathode.
Check the contacts of the
thermal element
Have the thermal element
replaced.
Pressure switch problem
or exhaust pipe with not
enough vacuum pressure.
Check or change the
pressure switch again.
Check or replace the
exhaust engine.
Check and close the door.
Check and clean the
exhaust pipes.
Problem with the tempera-
ture sensor or bad contact.
Check the contacts.
Check the temperature
sensor.