69
EN
Cleaning of exhaust pipes inside the furnace
The flue pipes inside the stove must be cleaned at least twice a year or when
about 500 kilograms of pellets have been burnt or the heater has been in
operation for more than 300 hours. Clean both ends of the pipes.
• Lift up the top cover to remove it.
• Remove the side cover.
• Use a hexagon socket key (4 mm) to remove 6 screws from the cover.
• Remove the 3 plate covers and the 3 sealing rings.
• Remove the ash from the exhaust pipes with an ash extractor.
• After cleaning, mount the cover plates in reverse order and make sure that
they are tight.