Adjustment range of the speed stages of the convection motor at different fire
power stages:
Fire power level
Range of the speed stages of the motor
Fire power level 1
All speed levels (1-5) are available, any speed is possible.
Fire power level 2-3
Only speed levels 3, 4 and 5 are available.
Fire power level 4-5
Only speed levels 4 and 5 are available.
Input of parameters for each power level
Note
: These settings have been configured at the factory and may only be
adjusted by qualified personnel!
Example
: [1A:050:1B:020:1C:019] means that in the first power stage the
screw motor stops for 5.0 seconds, works for 2.0 seconds, the speed of the
outlet motor is 19.
Exhaust engine speed
Stop time of the screw
motor
Operating time of the
screw motor
power level