4-2
n
Built-InSingle and Double Wall Ovens
COMPONENT ACCESS
REMOVING THE CONTROL PANEL
Note: The components for a Lower Oven are
accessed exactly like the components of the
Upper Oven except for the Oven Shutdown
Thermal Fuse (explained below).
Pull oven out of the cabinet approximately 4” to
expose 4 mounting screws (2 on each side).
Remove the screws and pull the control panel
and User Interface board out. Remove two
electrical connections.
The thermofuse is located just behind the control
panel. Remove the control panel and locate the
fuse in the center front of the controls section.
Remove electrical connections and release two
squeeze clips.
REMOVING THE APPLIANCE MANAGER
BOARD(S)
Pull oven out of the cabinet approximately 14” to
expose the top control service cover. Remove
mounting screws and lift service cover up.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
REMOVING THE CONTROL PANEL
THERMAL FUSE