6-20
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE / TEST
NOTE:
Possible Cause/Tests MUST be performed
in the sequence shown for each problem.
WON’T POWER UP.
(No response when a
cycle button is pressed.)
1. Supply connection. See TEST #1.
2. Check harness connections.
3. User interface assembly. See TEST #5.
WON’T START CYCLE
WHEN START BUTTON
IS PRESSED.
1. If number display flashes, check to be sure the
door is completely shut, and press and hold
down Start for about 1 second.
2. See TEST #2.
3. See TEST #6.
WON’T SHUT OFF
WHEN EXPECTED.
1. Check Pause/Cancel button. See TEST #5.
2. User interface assembly. See TEST #5.
3. Moisture Sensor. See TEST #4.
CONTROL WON’T
ACCEPT SELECTIONS.
User interface assembly. See TEST #5.
WON’T HEAT.
1. Heater. See TEST #3.
2. Check harness connections.
3. Check installation.
HEATS IN AIR CYCLE.
Temperature sensor. See TEST #3a.
SHUTS OFF BEFORE
CLOTHES ARE DRY.
Moisture Sensor. See TEST #4.
Figure 2.
Component Locations