2-10
3-Wire Connection: Power Supply Cord
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
1. External ground conductor screw
2. Neutral grounding wire (green/yellow)
3. Center silver-c olored terminal block screw
4. Neutral wire (white or center wire)
5. 3/4
″
(1.9 cm) UL listed strain relief
1
2
3
4
5
1.
Loosen or remove center terminal block
screw.
2.
Connect neutral wire (white or center wire)
of power supply cord to the center, silver-
colored terminal screw of the terminal
block. Tighten screw.
3.
Connect the other wires to outer terminal
block screws. Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
3-Wire Connection: Direct Wire
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of
extra length so dryer can be moved if needed.
Strip 3-1/2
″
(8.9 cm) of outer covering from end
of cable. Strip insulation back 1
″
(2.5 cm). If
using 3-wire cable with ground wire, cut bare
wire even with outer covering. Shape ends of
wires into a hook shape.
1.
Loosen or remove center terminal block
screw.
2.
Place the hooked end of the neutral wire
(white or center wire) of power supply
cable under the center screw of terminal
block (hook facing right). Squeeze hooked
end together. Tighten screw.
1. 3-wire receptacle (NEMA type 10-30R)
2. 3-w ire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. 3/4
″
(1.9 cm) UL listed strain relief
6. Ring terminals
7. Neutral (white or center wire)
1
2
4
3
5
6
7
When connecting to the terminal block, place
the hooked end of the wire under the screw of
the terminal block (hook facing right), squeeze
hooked end together and tighten screw. See
example below.
1
1. External ground conductor screw
2. Neutral grounding wire (green/yellow)
3. Center silver-c olored terminal block screw
4. Neutral wire (white or center wire)
5. 3/4
″
(1.9 cm) UL listed strain relief
1
2
3
4
5
Summary of Contents for Ensemble KEHS01PMT/WH