background image

4.

Carefully move range close to the

cabinet opening. Place the rack in oven.
Place level on rack, first side to side; then
front to back.

If the range is not level, adjust the feet
up or down. Turn leveling leg sleeves to
level range and to raise or lower range to
the desired countertop height.

5

remove
screws

bottom
vent

leveling leg
sleeves

Electrical requirements

F.

Connection at connection block must

be copper wire only.

If the house has aluminum wiring, follow
the procedure below:

a) Connect the aluminum wiring to the

copper wiring using special connectors
designed and Underwriters
Laboratories-listed for joining copper
to aluminum. Follow the electrical
connector manufacturer’s
recommended procedure.

b) Aluminum/copper connection must

conform with local codes and industry-
accepted wiring practices.

Copies of the standards listed may be 
obtained from:

* National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path and wire gauge are in
accordance with local codes.

Do not ground to a gas pipe.

Check with a qualified electrician if you
are not sure the range is properly
grounded.

Do not have a fuse in the neutral or
ground circuit.

This range must be connected to a
grounded metal, permanent wiring
system.

A.

A four-wire or three-wire, single

phase, 240-volt, 60-Hz, AC-only electrical
supply is required on a separate, 
50 amp circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker
is recommended. The fuse size must not
exceed the circuit rating of the range
specified on the model/serial rating plate
located on the horizontal surface below
the control panel.

B.

Wire sizes and connections must

conform to the requirements of the
National Electrical Code ANSI/NFPA 70 –
latest edition*, or CSA Standards C22.1-
94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 - latest edition** and all
local codes and ordinances.

C.

The range should be connected

directly to the fused disconnect or circuit
breaker box through flexible, armored or
non-metallic sheathed, copper cable. The
flexible, armored cable extending from
the fuse box or circuit breaker box
should be connected directly to the
junction box.  

D.

Locate the junction box to allow as

much slack as possible between the
junction box and the range so that the
range can be moved if servicing is ever
necessary. Do not cut the conduit.

E.

A U.L.- or CSA-listed conduit

connector must be provided at each end
of the power supply cable (at the range
and at the junction box). 

Installation

1.

Remove shipping materials, tape

and protective film from range. Keep
shipping pallet under range. Unpack the
burner grates, burner caps, simmer plate,
grille grate, drip tray, spill guard, wave
tray, wave plate, tile bezels, regulator,
backguard and island trim. Items are
either packaged in the range or on the
range. Parts shipped with range depend
on model ordered.

2.

Remove the two side trim pieces by

removing the 4 screws (2 per side).
Remove the bottom vent by removing
the 4 screws (2 on the top and 2 on the
side of the bottom vent). Slide the vent
down and pull toward you. Carefully lay
the parts to the side to avoid scratching
the stainless steel.

3.

Lay a piece of cardboard from side

packing on the floor behind range. Using
2 or more people, firmly grasp each side
of range. Lift range up about 3 inches (8
cm) and move it back until the range is
off shipping pallet. Set range on
cardboard to avoid damaging floor.

5.

Choose the correct bracket for your

installation.

• If the wall behind the range has no

baseboard or a baseboard up to 3/8"
(9.5 mm) thick, use the shorter 1" 
(2.5 cm) anti-tip bracket.

• If the wall behind the range has a

baseboard thicker than 3/8" (9.5 mm),
use the longer 1-3/4" (4.4 cm) anti-tip
bracket.

Locate a stud in wall behind range.
Measure distance from top of rear brace
to floor. Add 5/16" (7.9 mm) to
measurement to allow anti-tip bracket to
slide over rear brace. Use this final
measurement and mark a horizontal line
on wall where stud is located.

write down
this distance

rear
brace

WARNING

Excessive Weight Hazard

Use two or more people to move and
install range.

Failure to do so can result in back or
other injury.

Summary of Contents for 8302472A

Page 1: ...the surface below the control panel Model _______________________________ Serial ________________________________ Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 48 121 9 cm Commercial Style Dual Fuel Range with self cleaning thermal convection oven for residential use onl...

Page 2: ...nform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition installation codes WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Page 3: ... 8 cm clearance to back wall use the optional stainless steel island trim included with the range to cover the backguard mounting flanges 48 121 9 cm min upper cabinet width 48 1 4 122 6 cm opening width 20 50 8 cm 12 30 5 cm 5 1 2 14 cm 8 20 3 cm 18 45 7 cm upper cabinet to countertop gas line opening to be located in this area junction box to be located in this area 12 30 5 cm min clearance from...

Page 4: ...n the same room but external to the range and should be in a location that allows ease of opening and closing Do not block access to the shutoff valve to range shutoff valve open position G If rigid pipe is used as a gas supply line a combination of pipe fittings must be used to obtain an in line connection to the range All strains must be removed from the supply and fuel lines so range will be le...

Page 5: ... and ordinances C The range should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable The flexible armored cable extending from the fuse box or circuit breaker box should be connected directly to the junction box D Locate the junction box to allow as much slack as possible between the junction box and the range so tha...

Page 6: ...al 7B Where local codes permit connecting the frame ground conductor to the neutral white junction box wire not used for Canadian installations Figure 2 Grounded neutral junction box red wires white wire white and bare or green wires 3 wire cable from power supply black wires 4 wire cable from range U L or CSA listed conduit connector 1 Disconnect power 2 Connect the flexible armored cable from th...

Page 7: ...owing instructions Test all connections using an approved non corrosive leak detection solution Bubbles will show a leak Correct any leak found 14 Put a burner cap on each burner base Place burner grates over burner bases and caps 15 Reconnect power PF should appear in the clock displays Refer to your Use and Care Guide for instructions on using the electronic control 12 Open manual shutoff valve ...

Page 8: ...e flame Flame should be as small as possible without going out ports typical surface burner flame at highest setting 16 Electronic Ignition System initial lighting Surface burners use electronic ignitors in place of standing pilots When the cooktop control knob is pushed in and turned to the LITE position the system creates a spark to light the burner This sparking continues until the control knob...

Page 9: ... at www kitchenaid com When you call you will need the range model number and serial number Both numbers can be found on the model serial rating plate located on the surface below the control panel If you need service In the event that your KitchenAid appliance should need service call the dealer from whom you purchased the appliance or a KitchenAid designated service company A KitchenAid designat...

Page 10: ...WITCH 1 BRN BU V GRN W OR BU R Y R GY BK BK W BK W t BK P4 1 P4 2 P7 4 P7 2 P7 3 P3 1 P1 3 P5 4 P5 1 P5 3 P1 1 P1 5 TAN P7 1 W W TAN TAN R M BLOWER DOOR LOCK MOTOR LATCH R V P7 5 SUPPRESSOR WP 4451985 ELECTRONIC CONTROL RIGHT SLAVE DOUBLE LINE BREAK RELAY TOD NON RESETTABLE P9 1 P9 3 SEE LATCH ASSY Y ORG RS2 RS1 BK BK OFF AUTO LIGHT SWITCH LIGHT POWER SUPPLY ORG W W W R CONTROL POWER TRANSFORMER B...

Page 11: ...________ Pour toute question concernant caractéristiques utilisation performance pièces ou service téléphoner au 1 800 422 1230 ou consulter notre site Internet à l adresse www kitchenaid com IMPORTANT Lire et conserver ces instructions Cuisinière style commercial 121 9 cm 48 po deux combustibles avec four autonettoyant thermique à convection pour utilisation résidentielle seulement Dosseret néces...

Page 12: ... dégagements de séparation spécifiés sur la plaque signalétique On trouve la plaque signalétique et l étiquette d information sur les gaz combustibles sous le tableau de commande de l appareil L installation réalisée selon ces instructions doit être conforme aux dispositions des codes et règlements locaux En l absence d un code local l installation doit être conforme aux dispositions de la plus ré...

Page 13: ...6 cm 3 po maximum 50 8 cm 20 po 30 5 cm 12 po 14 cm 5 1 2 po 20 3 cm 8 po 45 7 cm 18 po entre placard mural et plan de travail Placer la canalisation de gaz dans cette zone Placer la boîte de connexion dans cette zone Dégagement de séparation de 30 5 cm 12 po min entre la cuisinière et un mur des matériaux combustibles des deux côtés de la cuisinière et au dessus de la surface de cuisson Dégagemen...

Page 14: ...manuel homologué doit être installé sur la canalisation d arrivée de gaz Ce robinet d arrêt devrait être situé dans la même pièce que la cuisinière à un emplacement permettant un accès aisé pour les manoeuvres d ouverture et de fermeture Ne pas entraver l accès au robinet d arrêt vers la cuisinière robinet d arrêt ouvert G Si la canalisation de gaz est une tuyauterie rigide utiliser une combinaiso...

Page 15: ...nière La liste des pièces fournies avec la cuisinière dépend du modèle commandé 3 Placer sur le sol derrière la cuisinière un morceau de carton provenant du côté de l emballage Saisir fermement la cuisinière de chaque côté participation deux ou plus de personnes Soulever la cuisinière d environ 8 cm 3 po et transférer la cuisinière de la palette à la feuille de carton éviter d endommager le planch...

Page 16: ...conduit homologation U L ou CSA câble à 4 conducteurs de la cuisinière conducteurs verts ou nus conducteurs blancs conducteurs rouges Figure 1 Conducteur neutre non relié à la terre 7B Si le code local permet le raccordement du conducteur de liaison à la terre connecté au châssis au conducteur neutre blanc dans la boîte de connexion cette configuration n est pas utilisée au Canada Figure 2 Conduct...

Page 17: ...rêt manuel de la canalisation de gaz Attendre quelques minutes pour que le gaz expulse l air de la canalisation installation du dosseret installation de la garniture pour îlot trou central pas utilisé 3 vis avant 4 vis nécessaires à l arrière mais pas représentées appliquer un produit d étanchéité conduit de raccordement flexible raccord droit 1 2 po robinet d arrêt manuel canalisation de gaz 1 2 ...

Page 18: ...orifices flamme typique d un brûleur standard de la table de cuisson pour le débit thermique maximum 17 Contrôle du fonctionnement de l élément du four Placer le bouton de sélection à la position BAKE cuisson au four Le message 350 F apparaît sur l afficheur Appuyer sur Enter Le témoin de préchauffage s illumine d abord puis la température commence à augmenter dans le four Lorsque le second témoin...

Page 19: ... cet appareil ménager KitchenAid contacter le marchand chez lequel il a été acheté ou contacter un établissement de service agréé par KitchenAid On peut trouver les noms et adresses des établissements de service agréés dans l annuaire local Pages jaunes à la rubrique Appareils électroménagers service et réparations Pour obtenir le nom et l adresse d un établissement de service après vente agréé on...

Page 20: ...P1 1 P1 5 TAN P7 1 BL BL TAN TAN R M VENTILATEUR R VI P7 5 SUPPRESSEUR WP 4451985 MODULE DE COMMANDE ÉLECTRONIQUE CÔTÉ DROIT ASSERVI RELAIS DISJONCTION BIPOLAIRE RELAIS DISJONCTION BIPOLAIRE TOD NON RÉARMABLE TOD NON RÉARMABLE P9 1 P9 3 SYSTÈME DE VERROUILLAGE SYSTÈME DE VERROUILLAGE JA OR RS2 RS1 N N OFF AUTO ALIMENTATION ÉCLAIRAGE ALIMENTATION ÉCLAIRAGE OR BL BL BL R TRANSFORMATEUR ALIMENTATION ...

Reviews: