KisanKraft
TM
2-STROKE PETROL ENGINE
: www.kisankraft.com
: +91.80. 22178200
Page 44 of 48
STORAGE
When releasing the engine from operation for more than 30 days, it must be serviced and
stored as follows with care to prevent the starting trouble or malfunction due to degeneration
of fuel.
1. Drain the fuel from the fuel tank and start to run the engine till it is stopped due to
use-up of fuel.
2. Wash the inside of fuel tank and fuel filter with white kerosene.
Use of fire is strictly prohibited
3. Removing the ignition plug, inject a small quantity of new engine oil through the
plughole. After idling slowly for few revolutions operating the recoil starter, install
the ignition plug. Pull the recoil starter again and stop it at the position where it is
felt heavy.
4. Clean the external surfaces with soft cloth and store it at a dry place free from
fires.
NOTE:
If the unit is left over without draining fuel, impurities in the fuel could clog the fuel
passages such as the carburetor, fuel filter, or others, and cause engine troubles.
Make sure to drain the fuel when storing the unit for a long period of time.
Sufficient care must be taken not to use fires at the vicinity when handling the fuel.