KisanKraft
TM
INTERCULTIVATOR
KK-IC-8626
: www.kisankraft.com
: +91.80. 22178200
Page 25 of 48
TROUBLESHOOTING
Case 1. Starting failure
Check
Probable Causes
Action to be taken
Fuel Tank
Incorrect fuel
Drain it and fill the tank with
correct fuel
Fuel Filter
Fuel filter is clogged
Clean the fuel filter.
Carburetor Adjustment
Screw
Out of normal range
Adjust the carburetor to normal
range
Sparking (no spark)
Spark plug is fouled
Clean the spark plug
Wet spark plug
Wipe the spark plug dry
Gap is incorrect
Correct (GAP: 0.6
~
0.7 mm)
Spark Plug
Disconnected
Retighten the spark plug
Case 2. Engine starts but does not keep running/ hard re-starting.
Check
Probable Causes
Action to be taken
Fuel Tank
Incorrect fuel
Drain it and fill the tank with
correct fuel
Carburetor
Adjustment Screw
Out of normal range
Adjust to normal range
Muffler,
Cylinder
(exhaust port)
Carbon is built-up
Wipe away the carbon
Air Cleaner
Clogged with dust
Clean the air cleaner
Cylinder Fin, Fan
Cover
Clogged with dust
Clean the cylinder fin, fan cover.