DR600 Service Manual
5
GPS cannot locate.
1. Check if the GPS settings are right. If not, Please reset it.
2. The antenna may be put in a close place, please put it in a
open place and relocate.
6
LED lights fail to
lightup on the the
front panel.
1. Check 13.6VDC input or 100-220VAC input and the connector
status on the power board.
2. Check the protective tube inside the socket if it is AC input.
3. Check the baseband board input voltage 13.6V and 3V3_OMAP
indicator light (LED6).
4. Check the status of front board interface and the flat cable.
7
Fails to be powered
on.
1. Check the power indicator on the front panel.
2. Check 13.6VDC input or 100-220VAC.
3. Check the baseband board input voltage 13.6V and
3V3_OMAP indicator (LED6).
4. Check the DIP switch (J4) code location on the side of
baseband board, and it should be in the start mode normally (1, 2,
3, off).
5. Check the baseband board OMAP 24M clock(Y2).
6. Connect the serial port (J23), and check the programming
printing information. Chec k if the program is loaded successfully
based on the print information and if the chip is initialized correctly.
8
The lights on the
baseband fail to light
up.
Check if the DC input port voltage is 13.2V, check whether
DCDC (U1) input is 13.2V if the voltage is right, if not, please
change the fuse F1. Or check if U1 output is 5V, if not, check U1
periphery or change U1. Or check PMU (U2) or change U2.
9
The alarm red light is
on or blinking on the
front panel after
powering on.
1. Check the flat cable between Tx module and Rx module.
2. Check Tx module interface (J17) and Rx module
interface(J15).
3. Check if the baseband board 12.8MHz clock output interface
(J6 or J7) is normal.
10
FPGA operating
LED is abnormal.
1. Check the status of the four lights (LED2, LED3, LED4,
LED5) beside the baseband board FPGA (U14), and check the
operating status of OMAP and FPGA. Normally, 20 seconds after
powering on, LED3 lights up, and LED2 and LED4 blinks
simultaneously, indicating the program is loaded successfully from
NAND; after another 40 seconds, LED3 and LED4 Lights up, and
LED2and LED5 blinks simultaneously, indicating CPU and FPGA
are started. If the program keeps failing on loading or starting,
please connect to the JTAG port (J2) to connect to the OMAP
simulator inspection program or reburn the program. If the burning
48
Summary of Contents for DR600
Page 1: ......
Page 37: ...DR600 Service Manual 33 ...
Page 110: ...DR600 Service Manual Figure 2 Rx Module Bottom Board PCB View 106 ...
Page 111: ...DR600 Service Manual Figure 3 Tx Module Top Board PCB View 107 ...
Page 113: ...DR600 Service Manual Figure 6 Baseband Mainboard Top Board PCB View 109 ...
Page 114: ...DR600 Service Manual Figure 7 Baseband Mainboard Bottom Board PCB View 110 ...
Page 116: ...DR600 Service Manual Figure 10 Power Board Top Board PCB View 112 ...
Page 118: ...DR600 Service Manual Figure 13 Enternet Board Top Board PCB View 114 ...
Page 119: ...DR600 Service Manual Figure 14 Enternet Board Bop Board PCB View 115 ...
Page 150: ...DR600 Service Manual Figure 21 Baseband Mainboard Schematic Diagram 146 ...