DR600 Service Manual
IF Processor Circuit
Figure 3-4 IF Processor
The 51.65MHz IF signal output from the IF amplifier enters the AD9864 via its pin 47, and it finishes the
second frequency mixing in the AD9864 to convert the fisrt IF to the second IF. The second IF signal is
converted to the digital signal through the ADC sampling and output from the SSI port, and the digital signal
is sent to FPGA for demodulation.
The reference frequency of AD9864 is 12.8MHz. The second local oscillation VCO is composed of external
oscillation tube, varactor, and related components. The VCO provides the 49.4MHz local oscillation signal.
The clock frequency of AD9864 is18MHz and it is generated by external LC resonance circuit.
Rx Module Frequency Generation Unit Circuit
The Rx Module Frequency Generation Unit Circuit is composed of two VCOs and one PLL. Two VCOs
cover the band of 400~435MHz and 435~470MHz respectively (VHF is 136~155MHz and 155~174MHz).
a. Working Principle of PLL
The 12.8MHz clock frequency provided by the baseband will enter the frequency divider for division, and
then the 3.2MHz phase detecting frequency will be generated. The signal generated by VCO enters the
PLL chip for frequency division, and goes into the PD to get compared in phase difference with the signal
generated by frequency division of reference clock, thus the continuous pulse current is generated. The
continuous pulse current passes the loop filter and will be converted to CV voltage via RC integral. The CV
voltage will be sent to the varactor, and it controls and adjusts the VCO output frequency until the CV
becomes constant. In the mean time, the PLL is locked, and the stable output frequency from VCO
passes the two buffer amplifier to enter the frequency mixer.
b. Working Principle of VCO
The Rx module employs two VCOs which cover the band of 348.35~383.35MHz and 383.35~418.35MHz
(VHF is 84.35~103.35MHz and 103.35~122.35MHz) respectively, and the switch of VCO is controlled by
the RXVCOSELECT signal. VCO employs three point capacitance oscillation circuit. The VCO that covers
the band of 348.35~383.35MHz (VHF is 84.35~103.35MHz) is composed of D1006~D1009
、
L1017
、
Q1011
7
Summary of Contents for DR600
Page 1: ......
Page 37: ...DR600 Service Manual 33 ...
Page 110: ...DR600 Service Manual Figure 2 Rx Module Bottom Board PCB View 106 ...
Page 111: ...DR600 Service Manual Figure 3 Tx Module Top Board PCB View 107 ...
Page 113: ...DR600 Service Manual Figure 6 Baseband Mainboard Top Board PCB View 109 ...
Page 114: ...DR600 Service Manual Figure 7 Baseband Mainboard Bottom Board PCB View 110 ...
Page 116: ...DR600 Service Manual Figure 10 Power Board Top Board PCB View 112 ...
Page 118: ...DR600 Service Manual Figure 13 Enternet Board Top Board PCB View 114 ...
Page 119: ...DR600 Service Manual Figure 14 Enternet Board Bop Board PCB View 115 ...
Page 150: ...DR600 Service Manual Figure 21 Baseband Mainboard Schematic Diagram 146 ...