When AC power supply is off, the electric relay (U1) is released. The DC is connected to U2 via the
electric relay (U1) contact. If the panel switch (J5) is on, the electric relay U2 will be switched on, so is the
repeater.
The panel switch (J5) is off, and U2 is released, which cut off the baseband DC power supply B13V
including the RF power supply R13V.
Over-voltage Protection
Figure 3-9 Over-voltage Circuit Protection
As the Figure 3-9 shows, the breakdown voltage of the voltage stabilizing diode is 18V+/-0.5V. If the input
DC volatage is over 18V+/-0.5V, the Q1 breaks over with Q2 being cut off, and the electric relay U2 will be
released to cut off the DC power supply B13V, including the RF power supply R13V.