background image

•  The power cable of this product must withstand

 

a minimum 10A  

 load.

  The main supply and interconnecting cables required for installation  

  of this unit are not included.

•  

This unit must be properly grounded.

•  

The disconnection of the product is acheived by incorporating a   

  switch in the fixed wiring in accordance with the wiring rules. The  

  heater must be isolated from the power by means of a disconnection  

  switch with a contact separation of at least 3mm. 

• 

The appliance is not intended for use by persons (including children)  

  with reduced physical, sensory or mental capabilities, or lack of   

  experience and knowledge, unless they have been given  

 

  supervision or instruction concerning use of the appliance by a    

  person responsible for their safety.

•  

Children should be supervised to ensure that they do not play with  

  the appliance.

2. Ducting

Put one end of the 100mm diameter ducting into the vent hole and 
connect to grille or cowl with one duct clip included.  Seal space 
around the grille using a suitable sealant.  An eggcrate grille is includ-
ed in the package to be used if installed in soffit. If installed in wall a 
weather proof cowl should be used (DCT0018).

INSTALLATION

A few minutes of planning can make a big difference to the installation 
time and also to your satisfaction with the function of the unit.

1. Cutting a vent

Locate the exterior grille location on a wall or soffit, then cut a 105 mm 
diameter hole to install grille/cowl.

Note: 

The length of duct is 3.0m. Make sure that from the centre of the 

units installated position there must be a distance within 3.0m to the 
outside vent. 

3. Suitable location

The heater must be installed at least 2.1m above the floor.  
The heater is most effective when you are standing directly beneath it, 

W all venting shown

wall
sealant

ducting

bathroom

heater

ceiling joist ceiling

fascia

duct clip

Terminal

 Blocks

4. Prepare the ceiling

Use this template to mark the hole 
outline on the ceiling.  Make sure a 
distance between the edges and 
wall is no less than 250mm. The 
distance from the ceiling board to 
the rooftop must be a minimum of 
220mm.

5. Remove the fascia

Remove 4 screw covers at 4 
corners of the fascia. Remove the 
screws hidden behind. Remove 
the fascia.

6. Wiring

Open the terminal block cover on 
the housing and make connection 
as the wiring diagram instructs, 
then reposition the terminal block 
cover.

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE 

Read and save these instructions!

Please use this card as hole cutting template 420mm×275mm.

EXHAUST

BLOWER

HEATER 1

HEATER 2

LIGHT

L

N

IN

220V-240V

M: Motor  C: Capacitor     : Thermal protector   

 IN

: Light lamp

      

MANROSE 

PTC Heater Fan & Light

WARNING

: Indicates that injury or death could occur if below 

Warnings

 are not followed.

This unit must be installed to comply with the appropriate council 

regulations and the Australia and New Zealand wiring rules 

AS/NZS3000:2000 or lastest edition thereof.
All wiring must be carried out by a Licensed Electrician in accor-

dance with all applicable codes and standards.  
Use this heater only as described in this manual. The manufacturer 

does not recommend any other use as this may cause fire, electric 

shock, or injury to persons. If you have questions, contact the manu-

facturer or local agent.
Make sure the power is off before the installation. 
For the purpose of avoiding any dangerous gas leaking into your 

bathroom, the duct vent of the heater must not be laid together with 

the duct vent  of air-fueled water heater or other open-fire appliances 

into the same flue.
The heater is to be installed so that switches and other controls 

cannot be touched by a person in the bath or shower.
This unit should not be installed directly above a shower or bathtub. 

The unit must not be installed in a position where water may splash 

onto the unit.

!

!

!

!

!

!

!

!

Dear customers

Please read all instructions before commencing installation.

CAUTION

: Possibility of damage to equipment, installation or premis-

es if below 

Cautions

 are not followed.

•  

The appliance shall, under no circumstances, be covered with    

  insulating material or similar material.

  Regulations concerning the discharge of air have to be fulfilled.

•  

The unit must not be installed beneath a fixed socket.

•  

The unit is designed for installation in flat ceilings only. Do not mount  

  it on a sloping ceiling or a vertical wall.

•  

Before commencing any cutting, check in the ceiling space that   

  there are no obstructions such as electrical wiring, hidden utilities  
  or ceiling joists and that there is sufficient height clearance for the  
  unit. Check that the electrical wiring can be routed from the wall   
  switches to the mounting location.

•  

Joists, beams and rafters shall not be cut or notched to install the  

 appliance.

so generally the unit would be mounted in a place where you would stand 
to dry yourself. For the exhaust fan to work efficiently, replacement air of a 
volume equivalent to what is being extracted must be able to enter the 
room. Generally, this air would be drawn under the door with a minimum 
space of 20mm. If the room is airtight, the fan extraction will be reduced.

Reviews: