Blow-off power
Blow-in fan power during blowing while burning off.
Purge time
Duration of air blow when burning fuel in burning off.
Purge break
Pause between blowing when burning off fuel in burning off.
Purge start
The brightness of the flame at which airflow starts, with fuel burnout
in extinguishing.
Purge stop
The brightness of the flame, at which the fan is turned off, when
burning fuel in extinguishing.
Cleaning
Cleaning time firing
up
Fan operation time while cleaning the furnace while firing up.
Burnout cleaning
time
Fan operation time during furnace shutdown.
Blow cleaning
The power of the burner blower fan during cleaning the furnace in
burning off and firing up.
Rotary cleaning
cycle
Time of operation of the burner rotary purge output and pause time of
the rotary purge of the burner.
Supervision
Supervision time
It is the time of the regulator's maximum stay in the SUPERVISION
mode. After this time, from the moment the regulator switches to the
SUPERVISION mode, the burner is automatically switched off. With
the Supervision time = 0 setting, Supervision mode is completely
disabled, with Supervision time = 255 Supervision mode is not
disabled.
Furnace power in
Supervision mode
Furnace power in Supervision mode.
Cycle time
Feeder cycle time in Supervision. Cycle time = feeding time + feeder
standstill time in Supervision.
Blow-in power
The power of the burner blower fan during work in Supervision. Select
a value that allows you to burn the fuel supplied in Supervision with
low emissions.
Minimum blowing
power
Minimal power of the burner blower fan that can be selected by the
user of the regulator. It is only used to limit the available fan power
range. It is not used for the fan control algorithm. It should be as
small as possible so that the fan rotates slowly and freely without
"hum".
Fuel shortage detection
time
The time is counted down after the flame brightness drops below the
value of Flame detection. After the countdown of this time, the
controller starts trying to fire up the burner, and after unsuccessful
attempts, it outputs the alarm Ignition failed attempt.
Maximum burner
temperature
Defines the maximum burner temperature at which the burner
overheating alarm will be issued.
6.2
Heater
Parametr
Description
Exchanger sensor
Enabling or disabling support for the heat exchanger temperature
sensor.
Blanking hysteresis
The parameter decides by how much above the set temperature the
burner is put out (or goes to supervision).
Temp. air to start
blowing
The temperature value of the air blown into the room at which the
exhaust fan will be turned on.
Temp. alarm blower
Maximum temperature of air blown into the room, above which the
alarm "Exceeded max. Heater temperature" will be reported.
Fan power heater
before heating the
exchanger
The power of the exhaust fan before heating the heat exchanger.
Airflow alarm
temperature hysteresis
If the value of the temperature of air blowing into the room exceeds
the value of Temp. alarm of the airflow by the hysteresis value in this
parameter, the alarm "Exceeded max. temperature of the heater" will