Active night-time decreases are signaled on
the screen by the symbol
.
The Reduction value parameter is used to set
the decrease temperature, one for all time
intervals. Night time reductions can be
defined separately for all days of the week in
the Schedule setting. One should choose
lowering the preset temperature for a given
time period. Time intervals for 24h are set
every 30 minutes.
Time intervals.
In the above example, from 00:00 to 06:00
the controller will reduce the preset
temperature by the value of the reduction.
From 06:00 to 09:00, the regulator will keep
the preset temperature at the preset level
(without decreases). From 09:00 to 15:00,
the regulator will lower the preset
temperature by the decrease value. From
15:00 to 22:00, the regulator will again
maintain the preset temperature at the
preset level (without decreases). From 22:00
to 23:59, the regulator will lower the preset
temperature by the decrease value.
The time period is ignored for the
setting Reduction value = 0.
3.8
Work according to a schedule
The regulator allows you to turn the furnance
on and off at defined time intervals. If there
is no demand for heat, e.g. in summer, the
stove can be turned off at a certain time,
thus reducing fuel consumption. To activate
time intervals, set in the menu:
Work on schedule
→
Turn on to Yes.
Switching the stove on and off in a time
period can be defined separately for all days
of the week in the Schedule setting.
Fuel level configuration
•
Activation of the fuel level indicator
To enable display of the fuel level, set the
parameter value:
Stove settings
→
Fuel level
→
Alarm level
to a value greater than zero, e.g. 10%.
• Support for the fuel level indicator
Each time after filling the fuel tank, press
and hold the current value of the fuel level,
then the prompt "Set the fuel level to 100%"
will appear.
Fuel level screen
After selecting and confirming YES, the fuel
level will be set to 100%.
Note: fuel can be added at any time, i.e. you
do not have to wait until the fuel tank is
completely empty. However, fuel should
always be added to the level of the container
corresponding to 100% and the level should
be set to 100% in the regulator as described
above.
•
A description of the action
The regulator calculates the fuel level based
on its current consumption. Factory settings
will not always correspond to the actual fuel
consumption of a given stove, therefore this
method requires level calibration by the user
of the regulator to operate correctly.
•
Calibration
Fill the fuel tank to the level corresponding to
a full load of 100%, and then set the
parameter value:
Furnance settings
→
Fuel level
→
Fuel
levelcalibration
→
Fuel level 100%
The decreasing fuel level in the fuel tank
should be monitored on an ongoing basis.
When the level drops to the expected
minimum, set the parameter value:
Furnance settings
→
Fuel level
→
Fuel level
calibration
→
Fuel level 0%
It is possible to skip the calibration process if
the parameters Feeder efficiency and Tank
capacity are set correctly.