Settings of operating modes of the built-in 
thermostat, which is responsible for heating 
in zone I. Thermostat support should be 
enabled by setting the Thermostat selection 
parameter to Built-in in the menu: Device 
settings. 

The operating mode is set in the menu: 

Built-in thermostat 

 Thermostat operation 

mode 

The following modes are available: 

• Schedule - the preset airflow temperature 
is determined in accordance with the set 
time schedule. The parameter Night 
(economic) temperature or Day (comfort) 
temperature is set in the menu: Built-in 
thermostat. 

• Economical - the controller works with a 
constant economic temperature, set in the 
parameter Night temperature. 

• Comfortable - the regulator works with a 
constant comfortable temperature, set in the 
parameter Day temperature. 

The built-in thermostat will turn on the 
heating of the 1st zone when the 
temperature in this room drops below the 
preset temperature minus Thermostat 
hysteresis, and will stop heating when the 
preset temperature in the room is reached. 

Room Panel 

The room panel connected to the regulator 
performs the function of a room thermostat 
and the furnace control panel and alarm 
signaling function. 

Additionally, 3 room panels for heating zones 
II, III and IV can be connected to the 
regulator, while the room panel (built-in 
thermostat) is available in the regulator 
module housing and is responsible for the 1st 
heating zone. 

After receiving a signal from the room panel 
(the temperature set in the room has been 
reached), the regulator closes the SP1 
damper actuator (actuator to the OFF 
position), and from the next room panel - it 
closes the SP2 damper and then another SP3 
damper. If all the room panels report no heat 
demand in all heating zones, the stove 
switches to the BURNING OFF mode, and 
then to the STAND-BY mode. The last SP4 

damper is closed only after the burner is 
extinguished and the exhaust fan is stopped. 

Feeder Test 

The controller allows you to test the burner 
feeder efficiency, which has a significant 
impact on the operation of the burner. The 
test is started with the parameter Feeder 
efficiency test in the menu: 

Furnace settings 

 Power modulation 

 

Feeder 

During the test, the necessarily full feeder 
feeds fuel to the additional container for the 
time set in the Performance test time. After 
this time, the fuel should be weighed in an 
additional container and the value entered 
into the Fuel weight parameter. 

In the event of emptying the main fuel tank 
and restarting the stove, activate the 
function of filling the burner feeder with the 
Feeder filling parameter. 

Informations 

The Information menu allows you to view the 
measured temperatures and to check which 
devices are currently turned on. 

Manual Control 

The controller allows for manual activation of 
executive  devices,  e.g.  fan,  feeder  motor, 
damper.  This  allows  you  to  check  whether 
the  devices  are  operational  and  properly 
connected. 

 

Access to the manual control menu 
is  possible  only  when  the  stove  is 
off. 

 

Long-term  activation  of  a  fan, 
feeder  or  other  actuating  device 
may lead to a hazard. 

3.9

 

Cooperation with the internet 
module 

The regulator can cooperate with the 
ecoNET300 internet module. It enables 
online monitoring and control of the 
regulator via Wi-Fi or LAN via the 
www.econet24.com website via a web 
browser or a convenient application for 
mobile devices.ecoNET.apk

 

Summary of Contents for ecoMAX920 P1-CH

Page 1: ...coMAX920P1 CH FOR BLOWING TYPE BOILER FOR SOLID FUEL I OPERATING AND INSTALLATION MANUAL ISSUE 1 0 09 2020 the device is not a standard equipment of the regulator ecoNET300 ecoNET apk ecoNET app www e...

Page 2: ...ction of the wires may damage the regulator The controller cannot be used in conditions of water vapor condensation and exposed to water MAIN PRINCIPLES OF PROPER FUZZY LOGIC FURNISHING The controller...

Page 3: ...MENTS 12 3 INSTALLATION OF THE CONTROL PANEL 12 4 WORKING MODULE INSTALLATION 12 5 IP PROTECTION RATE 12 6 ELECTRICAL CONNECTION 19 12 7 ELECTRICAL SCHEME 22 12 8 CONNECTION OF TEMPERATURE SENSORS 12...

Page 4: ...rinsically safe device ie in a failure condition it can be a source of a spark or high temperature which in the presence of flammable dusts or gases may cause a fire or explosion The surroundings of t...

Page 5: ...ept no liability for damage caused by failure to follow the instructions 4 Record keeping Please keep this installation and operating manual and all other applicable documentation carefully so that yo...

Page 6: ...Manual ecoMAX920P1 CH...

Page 7: ...FL Feeder Feeder efficiency Feeder efficiency time Efficiency feeder time Fuel weight Filling the feeder Regulation mode Standard Fuzzy Logic Fuel Level Alarm level Fuel Level calibration Cleaning Bur...

Page 8: ...econd method to turn on the stove Press the menu button and then press the button To turn off the stove press the menu button and then press button then the stove will go into the extinguishing proces...

Page 9: ...which translates into the actual burner power level The parameters of the burner power levels are available in the menu Furnance settings Power modulation The controller decides about the power of th...

Page 10: ...this will increase the temperature of the burner The parameters of the SUPERVISION mode must be selected so that the burner temperature in this mode gradually drops Incorrect settings can lead to over...

Page 11: ...ature Thanks to this when selecting a heating curve appropriate for a given building the room temperature heating zone will remain approximately constant regardless of the outside temperature Heating...

Page 12: ...ek in the Schedule setting Fuel level configuration Activation of the fuel level indicator To enable display of the fuel level set the parameter value Stove settings Fuel level Alarm level to a value...

Page 13: ...nd from the next room panel it closes the SP2 damper and then another SP3 damper If all the room panels report no heat demand in all heating zones the stove switches to the BURNING OFF mode and then t...

Page 14: ...14 ecoNET app...

Page 15: ...15...

Page 16: ...16 INSTALLATION MANUAL AND SERVICE SETTINGS ecoMAX920P1 CH...

Page 17: ...temperature sensor 5 supply temperature sensor 6 exhaust fan 7 burner fan and burner feeder 8 air damper actuator 9 room panel with a room thermostat function 10 external air intake 11 air supply duc...

Page 18: ...ions of wheel transport IP protection class The casing of the regulator provides IP20 protection The casing on the side of the terminal cover has the IP00 protection degree therefore the terminals mus...

Page 19: ...onnected to it You should remember about the safety rules related to electric shock The regulator must be equipped with a set of plugs inserted into the connectors for supplying 230V devices With a me...

Page 20: ...d cable 5 cable clamp 6 connector Separate electrical wiring from hot stove components especially flue pipes After connecting the wires it is absolutely necessary to put the cover back in its place Al...

Page 21: ...stat function HS heater exchanger temperature sensor CT4 ES type supply temperature sensor type CT4 FS exhaust gas temperature sensor type CT2 S FOS feeder temperature sensor type CT4 T thermostat int...

Page 22: ...all of the building usually it is the northern side in a roofed place The sensor should not be exposed to direct sunlight and rain Install the sensor at a height of at least 2 m above the ground away...

Page 23: ...T6 P weather External Temp C Min Nom Max 25 901 6 901 9 902 2 20 921 3 921 6 921 9 10 960 6 960 9 961 2 0 999 7 1000 0 1000 3 25 1096 9 1097 3 1097 7 50 1193 4 1194 0 1194 6 100 1384 2 1385 0 1385 8 1...

Page 24: ...iler it will supply 12V DC to terminals 43 44 After the furnace temperature drops below the parameter Reserve boiler activation temperature the regulator will stop supplying voltage to contacts 43 44...

Page 25: ...vice The safety temperature limiter must have a rated operating voltage of at least 230 V and should have the applicable approvals Dangerous voltage is present on terminals 1 2 If the STB is not insta...

Page 26: ...eration detection Fan speed multipier Burning off Max time of burning off Min time of burning off Blowing power Blowing time Blowing pause Blowing start Blowing stop Cleaning Cleaning time firing up C...

Page 27: ...eration time with minimum power after firing up The power is determined by the parameter Minimum power airflow job Thermostat mode Switches the burner into Thermostat mode where the burner works with...

Page 28: ...llows you to burn the fuel supplied in Supervision with low emissions Minimum blowing power Minimal power of the burner blower fan that can be selected by the user of the regulator It is only used to...

Page 29: ...rs Log out Restoring the service settings will also restore the settings from the main user menu Exit H Selecting Yes saves all service settings after changing parameters in the service menu Touch pan...

Page 30: ...ering up the regulator Checking the temperature sensor is described in point 12 11 6 4 Unsuccessful firing up attempt The alarm will occur after the third unsuccessful attempt to automatically fire up...

Page 31: ...nents 7 2 Replacing the mains fuse The mains fuse is located inside the controller housing The fuse may only be replaced by a suitably qualified person after disconnecting the mains supply Use time de...

Page 32: ...manually the limiter should be unlocked point Check the burner fan and replace if necessary The exhaust fan is not working Check if the mains fuse of the exhaust fan is not blown and replace if neces...

Page 33: ...33...

Page 34: ...34 ul Obornicka 71 62 002 Suchy Las Polska Tel 61 811 70 37 biuro kipi pl www kipi pl BDO 000179569...

Reviews: