13
Settings of operating modes of the built-in
thermostat, which is responsible for heating
in zone I. Thermostat support should be
enabled by setting the Thermostat selection
parameter to Built-in in the menu: Device
settings.
The operating mode is set in the menu:
Built-in thermostat
→
Thermostat operation
mode
The following modes are available:
• Schedule - the preset airflow temperature
is determined in accordance with the set
time schedule. The parameter Night
(economic) temperature or Day (comfort)
temperature is set in the menu: Built-in
thermostat.
• Economical - the controller works with a
constant economic temperature, set in the
parameter Night temperature.
• Comfortable - the regulator works with a
constant comfortable temperature, set in the
parameter Day temperature.
The built-in thermostat will turn on the
heating of the 1st zone when the
temperature in this room drops below the
preset temperature minus Thermostat
hysteresis, and will stop heating when the
preset temperature in the room is reached.
Room Panel
The room panel connected to the regulator
performs the function of a room thermostat
and the furnace control panel and alarm
signaling function.
Additionally, 3 room panels for heating zones
II, III and IV can be connected to the
regulator, while the room panel (built-in
thermostat) is available in the regulator
module housing and is responsible for the 1st
heating zone.
After receiving a signal from the room panel
(the temperature set in the room has been
reached), the regulator closes the SP1
damper actuator (actuator to the OFF
position), and from the next room panel - it
closes the SP2 damper and then another SP3
damper. If all the room panels report no heat
demand in all heating zones, the stove
switches to the BURNING OFF mode, and
then to the STAND-BY mode. The last SP4
damper is closed only after the burner is
extinguished and the exhaust fan is stopped.
Feeder Test
The controller allows you to test the burner
feeder efficiency, which has a significant
impact on the operation of the burner. The
test is started with the parameter Feeder
efficiency test in the menu:
Furnace settings
→
Power modulation
→
Feeder
During the test, the necessarily full feeder
feeds fuel to the additional container for the
time set in the Performance test time. After
this time, the fuel should be weighed in an
additional container and the value entered
into the Fuel weight parameter.
In the event of emptying the main fuel tank
and restarting the stove, activate the
function of filling the burner feeder with the
Feeder filling parameter.
Informations
The Information menu allows you to view the
measured temperatures and to check which
devices are currently turned on.
Manual Control
The controller allows for manual activation of
executive devices, e.g. fan, feeder motor,
damper. This allows you to check whether
the devices are operational and properly
connected.
Access to the manual control menu
is possible only when the stove is
off.
Long-term activation of a fan,
feeder or other actuating device
may lead to a hazard.
3.9
Cooperation with the internet
module
The regulator can cooperate with the
ecoNET300 internet module. It enables
online monitoring and control of the
regulator via Wi-Fi or LAN via the
www.econet24.com website via a web
browser or a convenient application for
mobile devices.ecoNET.apk