FP 50 D
Issue: 10/2010
10
»
Lens turret
- 2 lenses and manual lens change
- 2 lenses and automatic lens and aperture change
- electronic focusing control (option)
- 3 lenses and manual lens change
- 3 lenses automatic lens and aperture change
- electronic focusing control (option)
»
Automation system (option)
- DMP 1 Digital Matrix Programmer
- CCA 3 Cue Code Automation
- SA 2 Sequence Cinema Automation
- EMK 1 Electronic Automation System
»
Film gate cooling unit (option)
»
Water cooling system (from 4000 W lamp capacity on)
»
Reader for DOLBY / DTS / SDDS (option)
»
Rectifier
- Standard rectifier
- 65 to 85 A
- 75 to 95 A
- 100 to 140 A
- Kinoton rectifier
- KEX 110 (up to 110 A)
- KEX 170 (up to 170 A)
»
Film cleaner (option)
»
Operating manuals
2 .3
Installation
ATTENTION
U
The projector will be delivered completely wired and factory tested.
U
All installation has to be carried out by experts.
U
Only use suitable hoisting machines (crane, fork-lift).
U
Do not use unit parts as climbing aid.
U
Electrical connections have to be in accordance with local regulations and be
installed professionally.
2 .3 .1 Place of Installation, Place of Operation
»
The place on which unit will be installed must be even, solid and clean.
»
The projector’s dimensions is showed on the next page.
»
Requirements of the projection room:
- humidity:
40 to 60 %
- temperature:
15 to 25° C
- max. sea level: 2000 m