NOTE:
If a fixture loses its DMX signal it will hold it’s last DMX
command.
For this reason it is important to turn off the instrument
through a DMX command.
To turn off a fixture using the DMX ONÉ:
•
Set RATE/DIM to
DIM.
•
Turn
MASTER down to Minimum.
•
Turn off power switch.
C
D
B
H
G
F
E
A
A)
Circular Output Connector:
Provides electrical power to the
lamp head with the use of a 4Bank extension cable.
B)
DMX-In & DMX-Out:
DMX-IN receives DMX signals from
Dimmer Board, DMX-OUT relays DMX signal through to other
Fixtures or Instruments.
C)
Fuse:
Provides circuit protection.
Note: If Fuse is "blown" or
"open" replace with same type of fuse rating as marked.
D)
DMX TERMINATE Switch
: Terminates DMX signal at the end of
Fixture series.
E)
Individual Lamp / Fixture Switch
: Converts between
INDIVIDUAL LAMP and FIXTURE methods of DMX control.
F)
DMX Address:
Sets DMX Address of Fixture.
G)
Lamp Select:
Set to
4ft
for 4ft lamps and
2ft
for 2ft or 15”
lamps.
H)
Manual Switches:
Turns lamps on and off manually without
connecting DMX Cable to Ballast.
12
Summary of Contents for DMX-ONE
Page 1: ...Operation Manual DMX ONÉ ...