ULK2
Universal Light Kit (
Optional Accent Lighting Kit)
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian
National Electrical Code in Canada.
Contents of Kit:
[2] 12V Halogen Lamps
Lamp Plate with Insulated Studs & wiring
12VAC Transformer with 3 prong plug & wire connectors
Light Switch & Cover Plate c/w10ft wire c/w [1] Loose
Female & [1] Loose Male wire connector
Connect Switch Here
Lamp
Lamp
Bottom of Firebox
Inside Firebox
INSTALLATION:
STEP 1
: Remove false bottom to expose burner tube. Remove burner tube and cover plate as above. Remove old
sealant from opening.
STEP 2
: Insert lamp wires through access hole in firebox as above. Apply new sealant (Mill-Pac). Secure Lamp Plate
with screws.