ZRB46
Z46FK Fan Kit Installation
Fan Kit should be installed
before
facing material is applied or surround is installed. To
remove
fan for service, the burner
pan must be removed and work done through the opening (See
Burner System Removal
section).
1. Remove Lower Face Panel
(See
Removable Lower Face Panel
Section in manual).
2. Lift UHS Box out of Unit
3. Insert fan and place at right rear
corner of unit. See Component
Locations Section in manual.
4. Mount fan on tabs
5. Connect fan as per wiring diagram above.
Replace UHS Box and Lower Face Panel.
THERMODISC
Thermodisc
Located under
Burner pan
Fan Speed
Control
(Locate
Outside of
Fireplace)
VALVE
NOTE: Do not allow cords or wires to come into contact
with the firebox or the underside of the burner pan.
TAB
TAB
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this.
Before Servicing
1. Ensure all power supply is shut off.
2. Label all wires prior to disconnecting when servicing control. Wiring errors can cause improper and dangerous
operation.
3. For fan servicing: Vacuum and clean lint/dirt build-up on the fan blades and motor.
4. When resealing the Burner Pan, use
Millpac
.
19
Summary of Contents for ZRB46
Page 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31...
Page 41: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 41...
Page 42: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 42...
Page 63: ...PVCM Schematic Millivolt 63...
Page 67: ...PVCM Schematic IPI 67...
Page 68: ...68...