ZRB46
Surround
Dimensions
Surround Frame
Z46S1
Surround Frame
Z46S2
•
The Surround Frames are 1” thick, with a 3/4” space behind the frame.
•
When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”.
•
The Fireplace may be covered up to within 1/8” of the Fireplace Opening with non-combustible materials.
ZRB46
Surround
Clearances
1/8” Clearance
around opening
Maximum Depth for Facing
Materials is 3/4” When Using
Surround
16