16
ZDV3318 - Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Ceiling (from bottom of fireplace)
60 inches/150 cm
Top (from standoffs)
0 inches/0 mm
Louvered Unit
Top of 90 degree bend in Minimum
Enclosure of 37 3/4 to 40 inches
3 1/4 inches/140 mm / All Vent Systems
Enclosure over 40 inches
2 1/2 inches/38mm/All Vent Systems
CVCK Unit (non louvered)
Top of 90 degree bend in Minimum
Enclosure of 40.5inches to 43 inches
5 inches/38 mm / All Vent Systems
Enclosure over 43inches
2 1/2 inches/38mm All vent Systems
Top of Horizontal Pipe
1 1/2 inches/38 mm / All Vent Systems
Side & Bottom of Horizontal Pipe
1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp
Systems
(NOTE -Floor) if installing the
appliance directly on carpeting or
other combustible materials other
than wood flooring, the appliance
shall be installed on a metal or
wood panel, the full width and
depth of the appliance. Carpet
may extend 1 inch above the
floor of appliance.
For units with CVCK (Clear
View Circulating Kit) see
framing with CVCK to establish
floor heights
ZDV3622 - Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Ceiling (from bottom of fireplace)
60 inches/150 cm
Top (from standoffs)
0 inches/0 mm
Louvered Unit
Top of 90 degree bend in Minimum
Enclosure of 42 to 46 inches
5 1/2 inches/140 mm / All Vent Systems
Enclosure over 46 inches
2 1/2 inches/38mm/All Vent Systems
CVCK Unit (non louvered)
Top of 90 degree bend in Minimum
Enclosure of 44.5inches to 48.5 inches 5 inches/38 mm / All Vent Systems
Enclosure over 48.5inches
2 1/2 inches/38mm All vent Systems
Top of Horizontal Pipe
1 1/2 inches/38 mm / All Vent Systems
Side & Bottom of Horizontal Pipe
1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp
Systems
(NOTE -Floor) if installing the
appliance directly on carpeting or
other combustible materials other
than wood flooring, the appliance
shall be installed on a metal or
wood panel, the full width and
depth of the appliance. Carpet
may extend 1 inch above the
floor of appliance.
For units with CVCK (Clear
View Circulating Kit) see
framing with CVCK to establish
floor heights