Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for
Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard
in Canada.
THE ZDV3318, ZDV3318LP, ZDV3622N and ZDV3622LP MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES
AFTER FIRST SALE IN THE USA. IN CANADA THE ZDV3318, ZDV3318LP, ZDV3622N and ZDV3622LP MAY BE
INSTALLED IN MANUFACTURED (MOBILE) HOMES.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code
in Canada.
An appliance must be grounded to the steel chassis of the home with 8 ga. copper wire using a serrated or star washer to penetrate paint
or protective coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
Warning:
Do not compromise the structural integrity of the manufactured home wall, floor or ceiling, during
installation of appliance or venting.
For required venting components see venting installation in appropriate section of this manual.
Certified for installation in a bedroom or bed/sitting room. In Canada must be installed with listed milli volt thermostat. In USA
see local codes.