11
52.0" REQUIRES INSULATION SLEEVE
2.0"
34.0"
52.0"
42.0"
1/2" Gyproc
36.0"
MINIMUM FROM
BASE TO
CENTER OF
TERMINATION
MIN. LOW PROFILE
ENCLOSURES REQUIRES
INSULATION SLEEVE
NOTE
INSULATION SLEEVE MUST
COVER 7.0" FLEX PIPE FROM
FIREPLACE UP AND TO WALL.
SLEEVE FOR LOW PROFILE
ENCLOSURES MAXIMUM 34.0".
LOW PROFILE ENCLOSURE
42.0" TO 52.0" MUST MAINTAIN
A MINIMUM CLEARANCE OF
2.0" FROM TOP OF 7.0" FLEX
PIPE AND INSULATION SLEEVE.
52.0" AND HIGHER ENCLOSURE
MUST MAINTAIN 4.0" ABOVE 7.0"
FLEX PIPE WITHOUT INSULATION
SLEEVE.
NOTE
WITH USING DURA-VENT
PIPE AND ADAPTER MINIMUM
HEIGHT OF 52.0" MUST BE
MAINTAINED FOR PROPER
CLEARANCES. INSULATION
SLEEVE IS NOT REQUIRED.
THIS WILL LEAVE A 4.0"
MINIMUM CLEARANCE TO
COMBUSTIBLE TOP.
It is recommended for
Propane Horizontal
Installations
that the venting should be a minimum
of one foot vertical off the flue before the elbow on
any horizontal runs of one foot or greater. This
allows for cleaner combustion and greatly reduces
carboning and cleaning of glass. (Does not apply to
Back Flue Models).
NOTE:
Clearance to back of unit and/or sides of unit
framed into walls require 6” minimum clearance to com-
bustibles. We recommend using two (2 x 4) studs placed
against the wall as per framing diagrams. See Page 3 -
Locating your Appliance, for additional information.