background image

31

Parts List

PART NO.

DESCRIPTION

Fireplace Part Numbers

MDV38 SERIES  MULTI-SIDED DIRECT VENT FIREPLACE:

Listed for USA/Canada as a Decorative Appliance, Includes: Triple Burner, Up to
Three Viewing Areas, Milli Volt Sit Valve, Hi/Lo Adjustment, Wall Mount On/Off
Switch, Ember Ash Kit, Four and Seven Flue, Sloped Back, 39,000 BTU NG, 
38,000 BTU LP

MDVR38N

Multi-Sided Fireplace, c/w Right Burner (as above) Natural Gas

MDVR38LP

Multi-Sided Fireplace, c/w Right Burner (as above) Liquid Propane

MDVL38N

Multi-Sided Fireplace, c/w Left Burner (as above) Natural Gas

MDVL38LP

Multi-Sided Fireplace, c/w Left Burner (as above) Liquid Propane

FIREPLACE REQUIREMENTS

Log Sets: (Required for each unit)

LOGF38

Log Set - Five Piece Fibre Split Oak (MDV38)

Choose Your View: (Required for each unit)

M38PK

PENINSULA KIT - THREE SIDED VIEWING

- One Large Panel of Ceramic Glass, One Small Panel of Ceramic Glass

M38CK

CORNER KIT - TWO SIDED VIEWING

- One Small Panel of Ceramic Glass
- One Large Clearance Shield, One Large Solid Door Panel

M38SK

SEE-THROUGH KIT - TWO SIDED VIEWING

- One Large Panels of Ceramic Glass
- One Small Clearance Shield, One Small Solid Door Panel

GRILL KITS: (Required for each unit)

MGPKBP

Grill Kit Peninsula - Classic Polish Brass (Three Sets)

MGPKBA

Grill Kit Peninsula - Classic Antique Brass (Three Sets)

MGPKBC

Grill Kit Peninsula - Classic Chrome (Three Sets)

MGPKBL

Grill Kit Peninsula - Black (Three Sets)

MGPKAB

Grill Kit Peninsula - Antique Brass (Three Sets)

MGPKCR

Grill Kit Peninsula - Chrome (Three Sets)

MGCKBP

Grill Kit Corner - Classic Polish Brass (Two Sets)

MGCKBA

Grill Kit Corner - Classic Antique Brass (Two Sets)

MGCKBC

Grill Kit Corner - Classic Chrome (Two Sets)

MGCKBL

Grill Kit Corner - Black (Two Sets)

MGCKPB

Grill Kit Corner - Polish Brass (Two Sets)

MGCKAB

Grill Kit Corner - Antique Brass (Two Sets)

MGCKCR

Grill Kit Corner - Chrome (Two Sets)

MGSKBP

Grill Kit See-Through - Classic Polish Brass (Two Sets)

MGSKBA

Grill Kit See-Through - Classic Antique Brass (Two Sets)

MGSKBC

Grill Kit See-Through - Classic Chrome (Two Sets)

MGSKBL

Grill Kit See-Through - Black (Two Sets)

MGSKPB

Grill Kit See-Through - Polish Brass (Two Sets)

MGSKAB

Grill Kit See-Through - Antique Brass (Two Sets)

MGSKCR

Grill Kit See-Through -Chrome (Two Sets)

Bay Window Kits: for MDV38 Series Only

Bay Window Kits Consist of Black Upper Grill and Brass Lower Grill, Black Frame,
Three Piece Tempered Glass Viewing Area, and Ember Kit.

Z36BWAB

Bay Window (as above) with Antique Brass Louvres

Z36BWPB

Bay Window (as above) with Polish Brass Louvres

Z36BWCR

Bay Window (as above) with Chrome Louvres

MDV30 SERIES  MULTI-SIDED DIRECT VENT FIREPLACE:

Listed for USA/Canada as a Decorative Appliance, Includes: Triple Burner, Up to
Three Viewing Areas, Milli Volt Sit Valve Featuring less than 30 Sec Shut Down with
Hi/Lo Adjustment, Wall Mount On/Off Switch, Ember Ash One Large Panel of
Tempered Glass, Four and Seven Flue, Sloped Back, 30,000 BTU NG & LP

MDVR30N

Multi-Sided Fireplace, c/w Right Burner (as above) Natural Gas

MDVR30LP

Multi-Sided Fireplace, c/w Right Burner (as above) Liquid Propane

MDVL30N

Multi-Sided Fireplace, c/w Left Burner (as above) Natural Gas

MDVL30LP

Multi-Sided Fireplace, c/w Left Burner (as above) Liquid Propane

Log Sets: (Required for each unit)

LOGF38

Log Set - Five Piece Fibre Split Oak (MDV38)

Choose Your View: (Required for each unit)

M30PK

PENINSULA KIT - THREE SIDED VIEWING

- One Large Panel of Tempered Glass, One Small Panel of Tempered Glass

M30CK

CORNER KIT - TWO SIDED VIEWING

- One Small Panel of Tempered Glass
- One Large Clearance Shield, One Large Solid Door Panel

M30SK

SEE-THROUGH KIT - TWO SIDED VIEWING

- One Large Panel of Tempered Glass
- One Small Clearance Shield, One Small Solid Door Panel

Fireplace Accessories Options:

MDV38IS

Insulation Sleeve 3ft. - for Low Enclosures

MDV38RLE

Refractory Liner - End (Small Panel)

MDV38RLS

Refractory Liner - Side (Large Panel)

Z36SAB

Surround - Antique Brass (Coverage Old Style 33 3/4” H x 39 7/8” W)

Z36SCR

Surround - Chrome (Coverage New Style 34 1/2” H x 41 1/8” W)

Z36SPB

Surround -Polish Brass (Coverage New Style 34 1/2” H x 41 1/8” W)

Z36SLAB

Surround Slim Line - Antique Brass (Coverage 34 1/4” H x 37 1/2” W)

Z36SLCR

Surround Slim Line -Chrome (Coverage 34 1/4” H x 37 1/2” W)

Z36SLPB

Surround Slim Line - Polish Brass (Coverage 34 1/4” H x 37 1/2” W)

Z36SLBL

Surround Slim Line - Gun Metal Black (Coverage 34 1/4” H x 37 1/2” W)

Z1ADBL

Arch Door Frame - Black

Z36ADDX

Arch Door Frame - Deluxe Black  (352)

Z36ADTH

Arch Door Frame - Top Half Black  (353T)

Z36ADDA

Arch Door Frame - Double Arch  Black  (354)

Z36ADDD

Arch Door Frame - Double Door Arch Black  (355)

Z1ADAB

Arch Door Frame - Antique Black

Z36ADCR

Arch Door Frame - Chrome

Z1ADPB

Arch Door Frame - Polish Brass

Z36FK

Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing)

Z1MT

Thermostat Millivolt Wall Mount

Z80PT

Thermostat Programmable Digital Millivolt Wall Mount (1F80-40)

Z1RC

Remote Control Millivolt (On/Off with LED) (Model I)

ZART

Remote Control Thermostat Millivolt (Model K)

DCHS

Remote Control Heatshield

Replacement Burner Assembly

3800-BRNG

Burner Assembly - Right, Natural Gas - For Model MDVR38N

3800-BRLP

Burner Assembly - Right, Liquid Propane - For Model MDVR38LP

3800 - BLNG

Burner Assembly - Left, Natural Gas - For Model MDVL38N

3800-BLLP

Burner Assembly - Left, Liquid Propane - For Model MDVL38LP

3000-BRNG

Burner Assembly - Right, Natural Gas - For Model MDVR30N

3000-BRLP

Burner Assembly - Right, Liquid Propane - For Model MDVR30LP

3000-BLNG

Burner Assembly - Left, Natural Gas - For Model MDVL30N

3000-BLLP

Burner Assembly - Left, Liquid Propane - For Model MDVL30LP

Summary of Contents for MDVL30LP

Page 1: ...or any other appliance What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately cal...

Page 2: ...tory However due to the high temperature silicone components the paint will cure when heat is applied to the appliance as it is first used The following information applies to the curing process to ge...

Page 3: ...n 13 Door and Grill Installation 14 Bay Window Instructions 15 Brick Panel Installation 16 Ember Ash Bed Installation 16 Log Placement 17 18 Burner Replacement 20 Lighting Instructions 21 Gas Line Ins...

Page 4: ...THRU UNIT 41 062 PENINSULA UNIT 38 062 TOP VIEW 20 687 TOP VIEW 23 687 50 50 CORNER UNIT R H 38 062 REAR VIEW 16 125 36 125 16 125 21 687 15 50 36 062 29 75 SIDE VIEW END VIEW 32 625 31 875 UNIT DIMEN...

Page 5: ...D VERTICAL MAX Horizontal Run With Required Vertical Run LEFT CORNER TOP VIEW LEFT CORNER TOP VIEW MAX 36 0 LOCATING YOUR APPLIANCE Horizontal Run With Min Vertical Run RIGHT BURNER SYSTEM LEFT BURNER...

Page 6: ...oth sides of Fireplace for finishing material 3 The heat shield and rear standoff are equipped with nailing tabs Level Fireplace and nail or screw into place NOTE For Low Profile Enclosure Refer to Pa...

Page 7: ...k and Glowing Ember installation refer to PAGE 16 FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed flush with top of Fireplace Side facing to be installed to standoffs onl...

Page 8: ...r Combustible Enclosure Top NOTE This UNIT is not Load Bearing MIN 36 0 FIGURE 1 FIGURE 2 SEE THROUGH FIREPLACE SHOWN FIREPLACE ASSEMBLY 1 Mount Door Cover Figure 2 First apply a small bead of High He...

Page 9: ...FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only NOTE This UNIT is not Load Bearing Gyprock Gypro...

Page 10: ...closure top Insulation sleeve must be installed so that it covers 7 0 flex pipe from fireplace up and to wall sleeve Refer to Page 11 for any additional information PENINSULA INSTALLATION INSTRUCTIONS...

Page 11: ...9 FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only DRYWALL...

Page 12: ...Warning Combustible objects must not be placed on a non com bustible mantle unless the non combustible mantle meets the mini mum height and width requirements for a combustible mantle Clearance to Com...

Page 13: ...ND ADAPTER MINIMUM HEIGHT OF 52 0 MUST BE MAINTAINED FOR PROPER CLEARANCES INSULATION SLEEVE IS NOT REQUIRED THIS WILL LEAVE A 4 0 MINIMUM CLEARANCE TO COMBUSTIBLE TOP It is recommended for Propane Ho...

Page 14: ...under water 12 Do not operate appliance unless completely installed as per installa tion instructions Operating and Maintenance Instructions This gas appliance should be installed by a qualified insta...

Page 15: ...to bottom pan Refer to diagram for proper location Power cable to be routed through 6 x8 access hole 4 Connect power sensor and variable speed wall switch as shown in wiring diagram FAN KIT INSTALLATI...

Page 16: ...ws in both ends To install slide the head into one of the teardrop slots then slide Grill to opposite side repeat procedure These screws may have to be adjusted for proper alinement and length 3 All G...

Page 17: ...n each side as shown in illustration and install Brass Trim BAY WINDOW INSTRUCTIONS MDV38 SERIES CAUTION WARNING WHEN INSTALLING BAYWINDOW ASSEMBLY ORIGINAL GLASS WINDOW MUST REMAIN INSTALLED ON FIREP...

Page 18: ...avoid plugging them Any fine dust found in bottom of bag is not to be used 2 To apply Glowing Embers tear embers into pieces and place along perimeter Burners as well as on top of Crushed Rock in Grat...

Page 19: ...perimeter of the burner Do not place on middle burner as illus trated Care should be taken not to block burner ports Step 2 Take Log 4 and place onto burner using the two log tabs located on burner pa...

Page 20: ...5 rests on the shape of Log 4 Log Pin Step 5 Place Log 3 onto both Log 1 and Log 5 using the log pins as a guide Log Pin Step 6 Place Log 2 onto both Log 1 and 4 using the log pins as a guide Ensure...

Page 21: ...nit holding metal panel to firebox bottom remove the 2 screws and discard 2 Hold metal panel by the bottom and pull forward and down at the same time This will release the panel from the holder at the...

Page 22: ...eways as this may damage Venturi FIGURE 2 4 To replace reverse procedure VALVE REMOVALAND REPLACEMENT 1 To remove Valve first follow Burner instructions 2 Remove GAS line and Deflector Pan 3 To remove...

Page 23: ...er clockwise to ON 7 All models are supplied with a wall switch that turns the main burner on or off If main burner does not light immediately when you turn the gas control valve to ON ensure that the...

Page 24: ...t 3 When using copper or flex connector use only approved fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure d...

Page 25: ...the edge of terminal plate add 6 3 4 to clearances to arrive at center line NOTE Local Codes or Regulations may require different clearances Termination It is imperative that the vent termination be...

Page 26: ...section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe distance not having 90 bends will not fall into vent table standards See Fig B Venting Table Fro...

Page 27: ...ofile enclosure 2 5 rise per ft for horizontal runs with min vertical from Fireplace For installations other than Low Profile Enclosures top of horizontal with no sleeve requires a 2 5 clearance and 4...

Page 28: ...sulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed It is designed to keep insulation materials away from the chimne...

Page 29: ...protrudes approxi mately 2 to 3 inches past the 7 flex See Fig 1 Attach the 4 pipe to the termination first and secure with sealant and 4 screws washers then attach the 7 flex to the termination with...

Page 30: ...305 1000 306 1000 306 3800 312 3800 132 3800 134 3800 302 3600 301 5000 P025WS 1000 150GE RED 1000 150MP BLACK 1000 218 Z1MT 3800 128 EMBER I EMBER R ZIRC 3800 255 3800 252 3800 173 3800 171 3800 172...

Page 31: ...000 P136WR 1001 P129SI 1000 085 1000 214 1000 215 2000 080 2000 081 1001 P606SI NG 1001 P605SI LP Pilot Orifice LP 1001 P157SI Pilot Orifice NG 1001 P159SI MDV38 1000 255 NG 30 MDV38 1000 255 LP 50 MD...

Page 32: ...30 ZDV48GP ZDV7SC ZDV4SS ZDVRS ZDV7FCL ZDVWT ZDVSS ZDVST ZDV7FC ZDV4FC ZDVAIS ZDVFS ZDVAAF ZDVAF2 ZDVAF3 ZDVFK5 ZDVFK8 ZDVFK20 FDVHT FDVVT30...

Page 33: ...iple Burner Up to Three Viewing Areas Milli Volt Sit Valve Featuring less than 30 Sec Shut Down with Hi Lo Adjustment Wall Mount On Off Switch Ember Ash One Large Panel of Tempered Glass Four and Seve...

Page 34: ...129 SIT unified 1001 P157SI Orifice Pilot LP 977 157 SIT 1001 P159SI Orifice Pilot NG 977 159 SIT 1001 P508SI HT Cable 16 1001 P633SI Valve Nova LP Hi Lo 0820633 1001 P634SI Valve Nova NG Hi Lo 082063...

Page 35: ...rminals at wall switch If burner comes on replace defective Switch ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Gene...

Page 36: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Reviews: