Trouble Shooting The Gas Control System

WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT.

NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position.

Problem

Possible Causes

Corrective Action

Spark igniter will not light.

Defective or misaligned electrode

Check for spark at electrode and pilot: if no spark and electrode wire is

at pilot.

properly connected, replace igniter.

Defective igniter

Using a match, light pilot. If pilot lights, turn off pilot and push the red

(push-button)

button again. If pilot will not light - check gap at electrode and pilot 
should be 1/8” to 1/4” to have a strong spark.

Pilot will not stay lit after carefully

Defective thermocouple

Check pilot flame. Must impinge on generator and thermocouple.

following lighting instructions.

(flame switch where applicable) 

Clean and/or adjust pilot for maximum flame impingement on
generator and thermocouple.  Replace thermocouple if pilot will not 
hold.  (Hand tight 1/8 turn on replacement)

Defective valve magnet.

Replace valve, if pilot won’t hold after the thermocouple is replaced.

Pilot burning, no gas to burner,

Wall switch or wires

Check wall switch and wires for proper connections. Jumper wire

Valve knob “ON”, Wall

defective.

across terminals at wall switch. If burner comes on, replace defective

Switch “ON”

wall switch. If okay, jumper wires, across wall switch wires at valve.
If burner comes on, wires are faulty or connections are bad.

Generator may not be generating

Check generator with millivolt meter. Take reading at generator termi-

sufficient voltage.

nals of gas valve. Should read 325 millivolts minimum while holding 
valve knob depressed in pilot position and wall switch “off” Replace 
faulty generator if reading is below specified minimum.

Plugged burner orifice.

Check burner orifice for stoppage and remove.

Defective automatic valve

Remove wall switch wires from gas valve. Install jumper wires from 

operator.

top bottom terminals of gas valve. Turn valve on “ON”. If main burner
does not light, replace valve.

Frequent Pilot outage problem.

Pilot flame may be too low or

Clean and/or adjust pilot flame for maximum flame impingement

blowing (high) causing the pilot

on generator and thermocouple.

safety to drop out.

Flame lifts off burner and goes out

Inner 4” liner has come off flue

Attach 4” liner to flue or termination using      

in less than 30 seconds

or termination, flame is starving

screws, silicone and clamps as stated in manual

for oxygen

Flame lifts off burner on

Improper installation of firebrick.

Be sure to postion firebrick against firebox walls and

one side while the rest of

Firebrick is likely leaning.

be sure to use brick clips attached to the inner side

the flame remains lit.

of firebox.

Summary of Contents for MDVL30LP

Page 1: ...or any other appliance What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately cal...

Page 2: ...tory However due to the high temperature silicone components the paint will cure when heat is applied to the appliance as it is first used The following information applies to the curing process to ge...

Page 3: ...n 13 Door and Grill Installation 14 Bay Window Instructions 15 Brick Panel Installation 16 Ember Ash Bed Installation 16 Log Placement 17 18 Burner Replacement 20 Lighting Instructions 21 Gas Line Ins...

Page 4: ...THRU UNIT 41 062 PENINSULA UNIT 38 062 TOP VIEW 20 687 TOP VIEW 23 687 50 50 CORNER UNIT R H 38 062 REAR VIEW 16 125 36 125 16 125 21 687 15 50 36 062 29 75 SIDE VIEW END VIEW 32 625 31 875 UNIT DIMEN...

Page 5: ...D VERTICAL MAX Horizontal Run With Required Vertical Run LEFT CORNER TOP VIEW LEFT CORNER TOP VIEW MAX 36 0 LOCATING YOUR APPLIANCE Horizontal Run With Min Vertical Run RIGHT BURNER SYSTEM LEFT BURNER...

Page 6: ...oth sides of Fireplace for finishing material 3 The heat shield and rear standoff are equipped with nailing tabs Level Fireplace and nail or screw into place NOTE For Low Profile Enclosure Refer to Pa...

Page 7: ...k and Glowing Ember installation refer to PAGE 16 FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed flush with top of Fireplace Side facing to be installed to standoffs onl...

Page 8: ...r Combustible Enclosure Top NOTE This UNIT is not Load Bearing MIN 36 0 FIGURE 1 FIGURE 2 SEE THROUGH FIREPLACE SHOWN FIREPLACE ASSEMBLY 1 Mount Door Cover Figure 2 First apply a small bead of High He...

Page 9: ...FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only NOTE This UNIT is not Load Bearing Gyprock Gypro...

Page 10: ...closure top Insulation sleeve must be installed so that it covers 7 0 flex pipe from fireplace up and to wall sleeve Refer to Page 11 for any additional information PENINSULA INSTALLATION INSTRUCTIONS...

Page 11: ...9 FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only DRYWALL...

Page 12: ...Warning Combustible objects must not be placed on a non com bustible mantle unless the non combustible mantle meets the mini mum height and width requirements for a combustible mantle Clearance to Com...

Page 13: ...ND ADAPTER MINIMUM HEIGHT OF 52 0 MUST BE MAINTAINED FOR PROPER CLEARANCES INSULATION SLEEVE IS NOT REQUIRED THIS WILL LEAVE A 4 0 MINIMUM CLEARANCE TO COMBUSTIBLE TOP It is recommended for Propane Ho...

Page 14: ...under water 12 Do not operate appliance unless completely installed as per installa tion instructions Operating and Maintenance Instructions This gas appliance should be installed by a qualified insta...

Page 15: ...to bottom pan Refer to diagram for proper location Power cable to be routed through 6 x8 access hole 4 Connect power sensor and variable speed wall switch as shown in wiring diagram FAN KIT INSTALLATI...

Page 16: ...ws in both ends To install slide the head into one of the teardrop slots then slide Grill to opposite side repeat procedure These screws may have to be adjusted for proper alinement and length 3 All G...

Page 17: ...n each side as shown in illustration and install Brass Trim BAY WINDOW INSTRUCTIONS MDV38 SERIES CAUTION WARNING WHEN INSTALLING BAYWINDOW ASSEMBLY ORIGINAL GLASS WINDOW MUST REMAIN INSTALLED ON FIREP...

Page 18: ...avoid plugging them Any fine dust found in bottom of bag is not to be used 2 To apply Glowing Embers tear embers into pieces and place along perimeter Burners as well as on top of Crushed Rock in Grat...

Page 19: ...perimeter of the burner Do not place on middle burner as illus trated Care should be taken not to block burner ports Step 2 Take Log 4 and place onto burner using the two log tabs located on burner pa...

Page 20: ...5 rests on the shape of Log 4 Log Pin Step 5 Place Log 3 onto both Log 1 and Log 5 using the log pins as a guide Log Pin Step 6 Place Log 2 onto both Log 1 and 4 using the log pins as a guide Ensure...

Page 21: ...nit holding metal panel to firebox bottom remove the 2 screws and discard 2 Hold metal panel by the bottom and pull forward and down at the same time This will release the panel from the holder at the...

Page 22: ...eways as this may damage Venturi FIGURE 2 4 To replace reverse procedure VALVE REMOVALAND REPLACEMENT 1 To remove Valve first follow Burner instructions 2 Remove GAS line and Deflector Pan 3 To remove...

Page 23: ...er clockwise to ON 7 All models are supplied with a wall switch that turns the main burner on or off If main burner does not light immediately when you turn the gas control valve to ON ensure that the...

Page 24: ...t 3 When using copper or flex connector use only approved fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure d...

Page 25: ...the edge of terminal plate add 6 3 4 to clearances to arrive at center line NOTE Local Codes or Regulations may require different clearances Termination It is imperative that the vent termination be...

Page 26: ...section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe distance not having 90 bends will not fall into vent table standards See Fig B Venting Table Fro...

Page 27: ...ofile enclosure 2 5 rise per ft for horizontal runs with min vertical from Fireplace For installations other than Low Profile Enclosures top of horizontal with no sleeve requires a 2 5 clearance and 4...

Page 28: ...sulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed It is designed to keep insulation materials away from the chimne...

Page 29: ...protrudes approxi mately 2 to 3 inches past the 7 flex See Fig 1 Attach the 4 pipe to the termination first and secure with sealant and 4 screws washers then attach the 7 flex to the termination with...

Page 30: ...305 1000 306 1000 306 3800 312 3800 132 3800 134 3800 302 3600 301 5000 P025WS 1000 150GE RED 1000 150MP BLACK 1000 218 Z1MT 3800 128 EMBER I EMBER R ZIRC 3800 255 3800 252 3800 173 3800 171 3800 172...

Page 31: ...000 P136WR 1001 P129SI 1000 085 1000 214 1000 215 2000 080 2000 081 1001 P606SI NG 1001 P605SI LP Pilot Orifice LP 1001 P157SI Pilot Orifice NG 1001 P159SI MDV38 1000 255 NG 30 MDV38 1000 255 LP 50 MD...

Page 32: ...30 ZDV48GP ZDV7SC ZDV4SS ZDVRS ZDV7FCL ZDVWT ZDVSS ZDVST ZDV7FC ZDV4FC ZDVAIS ZDVFS ZDVAAF ZDVAF2 ZDVAF3 ZDVFK5 ZDVFK8 ZDVFK20 FDVHT FDVVT30...

Page 33: ...iple Burner Up to Three Viewing Areas Milli Volt Sit Valve Featuring less than 30 Sec Shut Down with Hi Lo Adjustment Wall Mount On Off Switch Ember Ash One Large Panel of Tempered Glass Four and Seve...

Page 34: ...129 SIT unified 1001 P157SI Orifice Pilot LP 977 157 SIT 1001 P159SI Orifice Pilot NG 977 159 SIT 1001 P508SI HT Cable 16 1001 P633SI Valve Nova LP Hi Lo 0820633 1001 P634SI Valve Nova NG Hi Lo 082063...

Page 35: ...rminals at wall switch If burner comes on replace defective Switch ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Gene...

Page 36: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Reviews: