10
Mantles
Depending on the width of the fireplace mantle, it may be installed
higher or lower from the top of the fireplace opening. See drawings for
proper installation height of your combustible mantel. Non-combustible
mantles may be installed at any height above the fireplace opening.
Non combustible materials such as brick, tile, etc. can extend up to or
over the front face of the fireplace (NO PORTION OF GRILL AREA
OR DOOR AREAS CAN BE COVERED).
Combustible material can extend flush to unit up to the top, bottom and
sides of fireplace to stand-offs.
If slim line brass surround is used, brick, tiles or other NON-COM-
BUSTIBLE materials may extend past the front of unit giving a
recessed appearance. For COMBUSTIBLE materials extending in front
of fireplace consult (Mantel and Mantel Leg Drawings).
If wide brass surround is used finish materials must be flush with front
of unit.
Note: When using paint or lacquer to finish the mantle, such paint
or lacquer must be heat resistant (250˚F) to prevent discoloration.
Warning:
Combustible objects must not be placed on a non-com-
bustible mantle unless the non-combustible mantle meets the mini-
mum height and width requirements for a combustible mantle.
Clearance to Combustibles
Back (of unit)
6 inches/152 mm
Sides (of unit in framing)
6 inches/152 mm
Vertical Pipe
1 inch/25 mm
Back (from standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Top of 90° Bend No Sleeve, in Enclosure over 52"
4 inches/102 mm
Top of Horizontal Pipe
2.5 inches/64 mm
Top Framing from Standoff
0 inches/0 mm
Bottom of Top Enclosure with Insulation Sleeve
42 inches/1067 mm
In Low Profile Enclosures from 42-52"
Top of Horizontal Pipe in Enclosure without Sleeve 12 inches/305 mm
Top of Horizontal Pipe in Low Profile Enclosure
with Insulation Sleeve
2 inches/51 mm
Note: See Mantel Chart
0"
2"
3"
4"
5"
6"
7"
6" 5" 4" 3" 2" 1" 0"
FRONT FACE OF FIRE PLACE
COMBUSTIBLE CLEARANCE FROM
THE FRONT OF THE FIRE PLACE
ADJACENT
W
ALL
FRAMING
NOTE:
Clearance to back of unit and/or sides of unit
framed into walls require 6” minimum clearance to com-
bustibles. We recommend using two (2 x 4) studs placed
against the wall as per framing diagrams. See Page 3 -
Locating your Appliance, for additional information.