background image

 

 

 

 

 

 Model Numbers:  ZCV39N, ZCV39NE, ZCV39NE2, ZCV39LP, ZCV39LPE, ZCV39LPE2 

ZCV42N, ZCV42NE, ZCV42NE2, ZCV42LP, ZCV42LPE, ZCV42LPE2 

Certified to:  ANSI Z21.88-2017 • CSA 2.33-2017, 

CSA 2.17-2017

  

Vented Gas Fireplace Heaters 

 

 Model Numbers:  ZCV39NH, ZCV39NHE, ZCV39NHE2, ZCV39LPH, ZCV39LPHE, ZCV39LPHE2 

ZCV42NH, ZCV42NHE, ZCV42NHE2, ZCV42LPH, ZCV42LPHE, ZCV42LPHE2 

Certified to:  ANSI Z21.88-2017 • CSA 2.33-2017, 

CSA 2.17-2017

 

Vented Gas Fireplace Heaters 

 

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

-WHAT TO DO IF YOU SMELL GAS 

Do not try to light any appliance. 
Do not touch any electrical switch; do not use any phone in your building. 
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 
If you cannot reach your gas supplier, call the fire department 

-Installation and service must be performed by a qualified installer, service agency or the gas 

supplier. 

  

Installation Instructions 

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA 

only) or mobile home, where not prohibited by local codes. 

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified kit is used.

 

INSTALLER: Leave this manual with the 

appliance. 
CONSUMER: Retain this manual for 

future reference. 

A Division of R-Co. Inc. 

2340 Logan Ave.    

Winnipeg, Manitoba Canada 

R2R 2V3  Ph.: (204) 632-1962 

Printed in Canada December 14, 2020  

Part# 39ZCV-MAN17 

For Propane Horizontal 

installations the venting must be 

an additional one foot above the 

minimum vertical rise off the flue 

before going horizontal. 

WARNING:

 If the information in these instructions are not followed exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life. 

 

BENTLEY 

VENTED GAS FIREPLACE HEATER: 

NOT FOR USE WITH SOLID FUEL. 

Summary of Contents for marquis ZCV39LPE2

Page 1: ...d service must be performed by a qualified installer service agency or the gas supplier Installation Instructions This appliance may be installed in an aftermarket permanently located manufactured hom...

Page 2: ...Fit Safety Screens 22 Basic Finishing 2 With S1 or S1PF Surround 23 24 Basic Finishing 3 Concrete Board Behind S2PF Surround 3 4 Maximum Total Thickness 25 Basic Finishing 4 Stone or Brick Around S2P...

Page 3: ...F Variable HI LO and Fan 70 Electronic Ignition Lighting Instructions 71 PROFLAME 2 Proflame 2 Parts List Basic System Parts List Configuration GTMFL 72 Proflame 2 Remote Control 73 Cold Climates CPI...

Page 4: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Page 5: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Page 6: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Page 7: ...mal shock Take care to prevent water from contacting the fireplace especially if it is hot See Through Units are suitable for an outdoor location but not on the outside wall of a house or other struct...

Page 8: ...with metal studs minimum 20 gauge Notice DurockR Brand Cement Board The manufacturer recommends CGC SheetrockR Brand DurabondR 90 Setting Type Drywall Compound rather than a ready mix product for fini...

Page 9: ...lectrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure groundi...

Page 10: ...Fireplace Fireplace to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 2 Nailing Tabs are located on each side of the front frame Nailing Tab Framing Stud Drywall Non...

Page 11: ...note of where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand o...

Page 12: ...Divider E Flat on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal por...

Page 13: ...Plus Rise of 1 4 Per Foot Fig 1 Framing for Horizontal Vent Termination See Installation of Side Wall Venting Section Vertical Venting MUST maintain 1 clearance to combustibles These structures are n...

Page 14: ...nd in Enclosure over 55 1 2 4 10 2cm VENTING SYSTEMS Top of Horizontal Pipe 1 1 2 3 8cm Side Bottom of Horizontal Pipe 1 2 5cm All Vent Systems Vertical Vent Pipe 1 2 5cm All Vent Systems Note If appl...

Page 15: ...1 2 x 41 This is to allow concrete board to be screwed to framing if used Recommended Non Combustible i e Concrete Board Screwed to Framing Recessed Combustible Wall Optional Refer to BASIC FINISHING...

Page 16: ...Divider E Flat on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal por...

Page 17: ...r LP Plus Rise of 1 4 Per Foot Fig 1 Framing for Horizontal Vent Termination See Installation of Side Wall Venting Section Vertical Venting MUST maintain 1 clearance to combustibles These structures a...

Page 18: ...Enclosure over 59 5 3 1 2 8 9 VENTING SYSTEMS Top of Horizontal Pipe 1 1 2 3 8cm Side Bottom of Horizontal Pipe 1 2 5cm All Vent Systems Vertical Vent Pipe 1 2 5cm All Vent Systems Note If appliance...

Page 19: ...used Recommended Non Combustible i e Concrete Board Screwed to Framing Recessed Combustible Wall Optional Recommended Non Combustible i e Concrete Board 42 5 8 x 44 Screwed to Framing 34 11 16 MIN 34...

Page 20: ...RTANT NOTE If installing tile brick or other non combustible material around the perimeter of the screen you MUST Leave 1 of the face exposed around the fireplace opening on the Bottom and Sides and 1...

Page 21: ...ol before touching glass or attempting to install or remove Child Safety Screen Screen is locked in place Contents of Kit 1 Child Safety Screen Ready to Install Assembly Instructions Attach screen to...

Page 22: ...ld Safety Screen Screen is locked in place Contents of Kit 1 Child Safety Screen Ready to Install Assembly Instructions Attach screen to fireplace as per instructions below Hook Lower Clip onto glass...

Page 23: ...e IMPORTANT NOTE If installing tile brick or other non combustible material around the perimeter of the surround you MUST Leave 4 of the face exposed around the fireplace opening on the Bottom and Sid...

Page 24: ...round Required Clearance ZCV39 Fireplace Opening S1 Surround S1PF Surround ZCV42 Fireplace Opening ZCV42 Fireplace Opening Required Clearance Required Clearance Bottom of Unit Bottom of Unit Bottom of...

Page 25: ...gs also Step 3 Concrete Board with optional Tile Lip shown below IMPORTANT NOTE If installing tile brick or other non combustible material around the perimeter of the S2PF2 Surround Maintain clearance...

Page 26: ...installing stone brick or other non combustible material around the perimeter of the surround you MUST Leave 1 3 4 of the face exposed around the fireplace opening on the Bottom and Sides and 1 15 16...

Page 27: ...rder IMPORTANT NOTE If installing tile brick or other non combustible material around the perimeter of the surround you MUST Leave 1 of the face exposed around the fireplace opening on the Bottom and...

Page 28: ...otruding facing materials i e concrete board brick or tile are to be used refer to Facing Material Dimension Requirements section A Tile Lip Kit is available ZCV TLK Follow instructions included with...

Page 29: ...ling stone brick or other material around the perimeter of the surround You MUST Leave 2 5 8 of the fireplace face exposed around the fireplace opening on the Sides 2 at the Bottom and 3 1 8 must be e...

Page 30: ...INISHED AREA IN FRONT OF FIREPLACE FLOOR HEARTH ETC MUST BE FLUSH WITH BOTTOM OF FIREPLACE WHEN USING DESIGNER DOORS INSTALL BACK FRAME OF DESIGNER DOOR ONTO FIREPLACE BEFORE FINISHING THE FIREPLACE F...

Page 31: ...llow instructions included with kit to use Back frame can be installed and used as tile lip also To Assemble Designer Door 1 Slide Screen into Front Frame 2 Set Hinge Sockets on Front Frame onto Hinge...

Page 32: ...36 1 2 1 15 16 1 3 4 ZCV39S1 Hearth Mount Surround 35 7 16 4 41 Top Only Required 4 1 16 No Bottom piece required ZCV39S1PF 4 Picture Frame Surround 37 7 16 4 41 4 1 16 4 ZCV39DD Designer Door 34 1 2...

Page 33: ...will not combust Check your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage to Non Combustible Mantels is that it may extend right up to th...

Page 34: ...will not combust Check your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage to Non Combustible Mantels is that it may extend right up to th...

Page 35: ...inserted removed from beneath fireplace through access panel opening Remove glass door first COMPONENT LOCATIONS See Each Section For Connections Wiring Remote Receiver IPI Module Fan Control Module...

Page 36: ...er Burner pan WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a prop...

Page 37: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Page 38: ...sition the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury ZCV39PL ZCV42PL Consists of 1...

Page 39: ...One Remove Log Holder Step Four Fix Side Liners in place using Liner Retainer Clips Step Five Reinstall Log Holder NOTE For Ceramic Glass units ZCV39NH ZCV39NEH ZCV39LPH ZCV39LPEH ZCV42NH ZCV42NEH ZCV...

Page 40: ...ile Handle with care 1 Using a utility knife measure and cut Back Liner removing the two side portions at the bottom 2 Make a cardboard template using the following dimensions 3 Use this template to m...

Page 41: ...Glass Tray DO NOT COVER PILOT SHIELD AREA WITH MEDIA WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may...

Page 42: ...New Sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada Contents of...

Page 43: ...tom if used along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to transformer Transformer can then be plugged in and the ho...

Page 44: ...back wall of firebox Log 3 is placed on right side Log Tabs Log 4 is placed on left side Log Tabs Log 5 is placed against right back wall of firebox WARNING Failure to position the parts in accordanc...

Page 45: ...on Burner in between Log 3 Grate Place on Log Holder behind Burner Pilot Place on Log Holder behind Burner Place on the center of the Burner Place in between Grate Bars as shown Place in between Grate...

Page 46: ...ght rear lights Place Log 4 on the center left site of the burner as shown Place Log 5 as shown 2 Embers Lava Rock Insulation Wool on Burner Lava Rock Vermiculite on Glass Tray 1 3 Embers Lava Rock Ve...

Page 47: ...ove Setup is complete WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or pe...

Page 48: ...ed objects MQ Glass can be placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in ch...

Page 49: ...mended for Propane appliances MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black MQG5ZG Decorative Glass Zircon Glacier Ice NOTE All glass is...

Page 50: ...ass Tray Place rocks randomly onto False Bottom and Burner Do not place directly on burner ports Not all rocks will be used on some installations If sooting occurs change position of or remove affecte...

Page 51: ...urner and Burner Ports Place these glowing ember chunks randomly May be used with or without other accessories NOTE Pilot Area Must Not Be Covered as delayed ignition can occur Pilot Shield should be...

Page 52: ...Logs 4 5 Logs 1 3 are placed against back wall of firebox Logs 4 5 are placed onto Log Tabs on Burner LOG 6 PLACEMENT NATURAL GAS LOG 6 PLACEMENT PROPANE Log 6 7 are placed as shown depending on which...

Page 53: ...these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Logs 8 10 are placed along Front Grate Lava Rock Vermiculite on...

Page 54: ...door in lower latches at an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit...

Page 55: ...for approximately 15 20minutes Use caution when removing broken glass Wear gloves Removal of the Glass Door 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and...

Page 56: ...at test pressures equal to or less than 1 2 PSIG 3 5 KPa Gas Specifications MODELS ZCV39N ZCV39NE ZCV39NE2 ZCV39LP ZCV39LPE ZCV39LPE2 ZCV39NH ZCV39NHE ZCV39NHE2 ZCV39LPH ZCV39LPHE ZCV39LPHE2 ZCV42N Z...

Page 57: ...ly the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then conti...

Page 58: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Page 59: ...1 16 1000 253 closed 1000 253 closed Fully Open Fully Open 1002 P012SI 907 012 39ZCV CKNGI 42ZCV CKNGI NG Conversion IPI 1001 P166SI 62 977 166 38 38 1000 253 closed 1000 253 closed 1 8 1 8 1002 P016...

Page 60: ...m IMPORTANT Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTING Warning This conversion kit shall be installed by a qualified service agency in accordance...

Page 61: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Page 62: ...Gas Conversion for Modulator PART C 62...

Page 63: ...ssembly upward to remove it from the firebox cavity Installation is the reverse of these steps Ensure that the mounting surface is clean Use fresh Black Mill Pac to reseal the burner pan WARNING Turn...

Page 64: ...ck This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery backup is that in the case of a power failure the applia...

Page 65: ...splay on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set...

Page 66: ...P 977 168 35 IPI 11 1002 P012SI IPI Stepper Kit LP 907 012 12 1002 P013SI IPI Stepper Kit NG 907 013 13 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 14 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 15 1002 P01...

Page 67: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 67...

Page 68: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 68...

Page 69: ...er Adapter P N 1002 P850si The Remote Receiver IPI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the...

Page 70: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 70...

Page 71: ...clockwise to off Located behind the access panel 7 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above...

Page 72: ...13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 1...

Page 73: ...d to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 module may now be turned on off manually x4 co...

Page 74: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...

Page 75: ...Proflame 2 Remote Control 75...

Page 76: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 76...

Page 77: ...77...

Page 78: ...3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m Notes 2 M Clearance under veranda porch deck or balcony 12 in 30 cm 12 in 30 cm N Where a ve...

Page 79: ...ends place spring in bend or before and after See Fig 1 Horizontal runs require support metal straps every 2 feet In offset installation support straps should be used to stabilize pipe Expand 4 and 7...

Page 80: ...e wall thimble to weather proof After installing the vent termination double check to make sure the pipe extends properly through wall thimble and into vent termination 7 Before joining pipes to firep...

Page 81: ...he number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of fl...

Page 82: ...w well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination Do not enclose the Snorkel within a wa...

Page 83: ...rulers or by using a roof pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the sh...

Page 84: ...upport configuration B Flex bend configuration C Termination mounting Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requireme...

Page 85: ...tion does not apply to this installation Before installing the appliance using this method contact the Authority Having Jurisdiction to determine if this installation is acceptable in your area HARD P...

Page 86: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Page 87: ...IFIED ELECTRICIAN MAIN WIRING HARNESS DOUBLE POLE SWITCH MV SYSTEMS ONLY IPI SYSTEM MAIN WIRING HARNESS POWER VENT CONTROL MODULE NOTE Fireplace glass door must be removed to Install or remove Power V...

Page 88: ...ZDVDFA Duravent Adapter for Sloped Flue Termination End ZDVDIA Duravent Hard Pipe Adapter used to connect 4x6 8 to 5 8 Hard Pipe Note Must use a one foot section of 5 8 DV hard pipe not supplied to c...

Page 89: ...lack MQLOG F9 Log Set 9pcs MQ39D Driftwood Log Set 4pcs MQSTONE Decorative Stones MQROCK2 Rock Set Natural MQROCK3 Rock Set Multi Color MQEMBER Glowing Embers MQG5W Decorative Glass 1 2 White 5LB MQG5...

Page 90: ...4 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 2000 080 Thermodisc 2450 For Blower 1000 306 Thermalcord Adhesive Back for Door Frame 1000 085 Cont...

Page 91: ...Set Natural MQROCK3 Rock Set Multi Color MQEMBER Glowing Embers MQG5W Decorative Glass 1 2 White 5LB MQG5A Decorative Ember Glass Cobalt Blue 5LB MQG5B Decorative Ember Glass Black 5LB MQG5ZG Decorati...

Page 92: ...ss State Size 2000 080 Thermodisc 2450 For Blower 1000 306 Thermalcord Adhesive Back for Door Frame 1000 085 Control Variable Speed KBWC 13BV FP15GC Stainless Steel Gas Connector Kingsman Fireplace Ve...

Page 93: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...