General Vent Installation Information
This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex
(Z-Flex) venting kits and components specifically approved and LABELED for this stove may be used. This appliance is also
approved for use with Simpson Dura-vent Direct Vent system (Model DV-GS Series), and AmeriVent Direct Vent Pipe
System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
Simpson Dura-vent, AmeriVent, and Selkirk Direct Temp
When using Simpson Duravent, AmeriVent pipe, ICC Excel Direct, Metal Fab Sure-Seal DV, or Selkirk Direct Temp a Dura-
vent adapter must be used (part # Z57DFA). Follow installation instructions provided by the appropriate manufacturer for
installation of pipe, and adhere to the clearance to combustibles provided in this manual. Apply a bead of Mill Pac high temp
sealant to all joints of pipes, adapters and termination as recommended.
Eight Inch Hard Pipe Adapter for MQRB5143 Infinite Series (Z57DFA)
1. Remove the two [2] Standoffs at the
vented end of the Fireplace.
2. Apply RTV Red Silicone to the
underside of the Adapter Plate around
the perimeter of the screw holes.
3. Fasten Adapter Plate to the top of the
unit using the supplied DT Screws.
4. Replace the Standoffs.
Flex Pipe Venting
Flex pipe is shipped in an unexpanded length. Therefore, when installing the pipe, expand it completely and then cut off the
remaining length. A flex pipe can be expanded to twice their shipped length (e.g. 4ft. to 8ft).
Do not use more than 2 couplers to extend short pipes. Single sections are preferred in an installation attaching at the
fireplace and termination.
Place the spring spaces provided approximately every two feet to stabilize 5" flex in the center of 7" flex. When forming
bends place spring in bend or before and after (see Figure 2).
ONLY VENTING COMPONENTS SPECIFICALLY APPROVED AND LABELED FOR THIS FIREPLACE MAY BE USED.
Termination
It is imperative that the vent termination be located observing the minimum clearances as shown. There must not be any
obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination plate.
Do not locate termination where excessive snow or ice build-up may occur. Be sure to check vent termination area after
snow falls and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not
directed towards vent termination area.
Venting terminal shall not be recessed into a wall or siding.
WARNING: DO NOT mix parts from different systems unless stated in the manual.
Contents: 1 ea. 8” Adapter Plate
6ea. DT Screws
Summary of Contents for Marquis Infinite MQRB5143LP
Page 30: ...30 Millivolt System Lighting and Burner Control...
Page 39: ...39...
Page 41: ...41 Photos Bottom of Unit with IPI Module Light Module IPI Valve...
Page 42: ...42 Close up View of IPI Module Inside of IPI Module...
Page 43: ...43 IPI Valve IPI Valve...
Page 44: ...44 Millivolt Valve Light Module Millivolt Valve...
Page 49: ...49 Venting Examples All horizontal runs have a minimum rise per foot...
Page 57: ...57 Warranty...