28
Valve Access Cover Removal
Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert
fingers into holes in Access Panel and lift out. When replacing Access Panel, engage Tabs into Slots in Bracket.
MQRB5143 Removable Lower Face Panel
Installers Note:
Once the installation is complete attach the Lower Face Panel. Insert two [2] screws on each side and seven [7] screws at
the bottom of the Lower Face Panel. Place on the Valve Access Cover.
The Lower Face Panel must be on the unit
Before
Facing Materials are applied.
Lower Ledge of Lower Face Panel Must be
Under
the Fireplace. Surround will not fit otherwise.
Note:
Once Facing Materials are applied, removal of the Lower Face Panel will not be possible.
Summary of Contents for Marquis Infinite MQRB5143LP
Page 30: ...30 Millivolt System Lighting and Burner Control...
Page 39: ...39...
Page 41: ...41 Photos Bottom of Unit with IPI Module Light Module IPI Valve...
Page 42: ...42 Close up View of IPI Module Inside of IPI Module...
Page 43: ...43 IPI Valve IPI Valve...
Page 44: ...44 Millivolt Valve Light Module Millivolt Valve...
Page 49: ...49 Venting Examples All horizontal runs have a minimum rise per foot...
Page 57: ...57 Warranty...