32
MQRB5143 Gas Conversion
or Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE.
Kit Number
Description Pilot
Orifice
Burner
Orifice
Nipple
Air Shutter
Hi/Lo Regulator
5143MQ-CKLP LP
Conversion
1001-P167SI #46 1000-253closed 3/8” 1001-P202SI
5143MQ-CKNG NG
Conversion
1001-P165SI #30 1000-253closed
1/32” 1001-P201SI
5143MQ-CKLPI LP
Conversion
1001-P168si #46
1000-253closed 3/8” 1002-P014si
5143MQ-CKNGI NG
Conversion
1001-P166si #30
1000-253closed
1/32” 1002-P016si
Caution: the gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
1. The Burner Tube must be removed from the Burner Pan
Assembly (See
Burner Tube Removal
). Adjust the Air Shutter
to the correct Primary Air setting as specified in the manual or
on the label plate. To adjust the Primary Air setting, loosen
screw on the side of the Air Shutter and rotate to the correct
opening using a drill bit or tape measure. Retighten screw.
2. Remove the Main Orifice using a ½” wrench and replace with the
new Conversion Orifice which came with the Conversion Kit.
3. Replace the Burner Tube. Install the new Pilot Orifice (See
Pilot
Conversion
) and Hi/Lo valve regulator by following instructions
supplied with the Conversion Kit.
Refer to “
Gas Specifications Chart
” in this Manual.
IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING.
-Warning-
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage, personal injury or
loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit.
Summary of Contents for Marquis Infinite MQRB5143LP
Page 30: ...30 Millivolt System Lighting and Burner Control...
Page 39: ...39...
Page 41: ...41 Photos Bottom of Unit with IPI Module Light Module IPI Valve...
Page 42: ...42 Close up View of IPI Module Inside of IPI Module...
Page 43: ...43 IPI Valve IPI Valve...
Page 44: ...44 Millivolt Valve Light Module Millivolt Valve...
Page 49: ...49 Venting Examples All horizontal runs have a minimum rise per foot...
Page 57: ...57 Warranty...