MQZCVBG34
ULK5-2 Halogen Light Kit
Option
STEP 1:
Remove Media Tray and Cover Plate. Place ULK
Transformer in position.
STEP 2:
Remove old sealant around exposed opening.
Apply New Sealant (Mill-Pac).
Insert wires on Lamp
Plate through opening. Secure Lamp Plate with screws.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian
National Electrical Code in Canada.
Contents of Kit:
•
[2] 12V Halogen Lamps
•
Lamp Plate with Insulated Studs & wiring
•
12VAC Transformer with wire connectors
•
(Millivolt & P1 Only) Light Switch & Cover Plate c/w10ft wire c/w
[1] Loose Female & [1] Loose Male wire connector
Inside Firebox
Bottom of Firebox
Connect Switch Here for
Millivolt & Proflame 1
Lamps
Lamps
Millivolt & Proflame 1
Power Connection
Proflame 2 Power
Connection
Cover Plate
Media Tray
Bottom of Lamp Plate
Top of Lamp Plate
STEP 3:
Wire Connections- Refer to schematic at top right of page.
Connect wires from Bottom of Lamp Plate to Red wires on ULK Transformer.
Proflame 2-
Plug Yellow connector into White lead from Proflame 2 Module.
See next page for Lamp installation in firebox.
ULK Transformer
LAMP PLATE
PROFLAME 2
Switch & Wire
provided for Millivolt &
Proflame 1 Units only
36