-Facing Requirements
Unit may be covered with combustible material (i.e. drywall) up to the fireplace opening.
MQZCVBG34
- Using Tile Lip
VALVE
IPI
SYSTEM
FIREPLACE CHASE MUST BE VENTED AT
THE TOP OF THE ENCLOSURE.
•
Minimum 90 square inches free air opening for
grills (V34EG & V34EGS).
• Minimum 2-1/8” Gap at top of enclosure for
Open Top chases.
Do not drive screws into
these highlighted areas.
Do not drive screws into
fireplace front. Facing
materials must be attached
to framing.
FRONT
A Tile Lip is supplied for attachment above the fireplace opening only.
This can be used as a standard tile edging or as a mount bracket for other
surfaces like drywall or plywood.
Set to desired height and attach through holes in face of fireplace.
For a complete Tile Lip Kit order ZBG34-TLK.
SIDE
26