ZCVRB60 -Framing Dimensions –Vented Chase -Ventilation Plates Removed
Determine whether face of fireplace will be:
Flush with finished wall (e.g., for surround, cultured stone or other
covering).
Flush with framing (for a Flat Wall appearance).
Refer to Nailing Tab Guide section also.
Vertical Venting MUST maintain 1”
clearance to combustibles.
These structures are not load bearing.
Note: If using optional surround, maximum
thickness for facing material is 3/4”.
Recessed- VL60EGS Grills
Recessed- VL60EG Grill
Sealed
Enclosure
Top
Sealed Enclosure Top
HEAT CANNOT BE DISCHARGED INTO THE WALLS,
FLOOR, OR CEILING.
Heat must exit through the
required vented chase opening near the ceiling.
If using insulation in vented chase (i.e. for outside wall),
wall board / drywall is required to support all insulation.
Vented chase must be clean and free of all debris (i.e.
loose insulation, pieces of wood, etc.).
76”
Minimum
Enclosure
12”
12”
9”
200 Square inch opening must be within
3/4” of top of the Sealed Enclosure Top.
For VL60EGS Side Grills:
15-1/4” x 6-5/8” Openings
must be within 3/4” of Sealed
Enclosure Top.
For VL60EG Grill:
60-5/8” x 3-5/8”
Opening must be
within 3/4” of
Sealed Enclosure
Top.
Framing for Vent Termination
(See
Venting
Section)
76”
Minimum
Enclosure
56”
MIN
39-3/4”
76”
Minimum
Enclosure
Must be within 3/4” of
top of the Sealed
Enclosure Top.
Sealed Enclosure Top
Optional
Recess
Sealed Enclosure Top
Must be within 3/4” of
top of the Sealed
Enclosure Top.
Grill
Opening
3-5/8”
39-3/4”
19-1/4”
56” MIN
Plus Rise of
1/4” Per
Foot
56”
MIN
39-3/4”
76”
Minimum
Enclosure
Optional
Recess
67”
Facing
Material