ZCVRB60 – Vented Chase - Optional Recessed Cavity Dimensions
•
Recessed Cavity may begin immediately above top header (i.e. 4” for 2 x 4 with drywall).
•
Television should be minimum 1” away from opening of Vented Chase.
3-1/2”Maximum
Depth of Recess
(2 x 4 Header plus Drywall)
1” Minimum
Clearance
from TV to
Vented Grill
Opening
76”
MINIMUM
ENCLOSURE
HEAT CANNOT BE DISCHARGED INTO THE WALLS,
FLOOR, OR CEILING. Heat must exit through the
required vented chase opening near the ceiling.
If using insulation in vented chase (i.e. for outside wall),
wall board / drywall is required to support all insulation.
Vented chase must be clean and free of all debris (i.e.
loose insulation, pieces of wood, etc.).
Maximum 3/4” from Enclosure Top
to Grill Opening
Notice:
Granite, tile, or other facing materials are not
covered by the fireplace warranty. Natural stone, tile,
and other facing materials may crack or discolor (i.e.
yellowing of lighter colored materials).
NOTE: THESE ISSUES CAN BE AVOIDED IF THE
CHASE IS VENTED.
Televisions are not covered by fireplace warranty.
3-5/16”
MIN
56”
MINIMUM
TERMINATION
HEIGHT
39-3/4”
HEADER
29-1/2”
TOP OF
OPENING
76” Minimum ceiling height from bottom of fireplace
Finishing
Materials
Top of Sealed Enclosure
15-1/4”
MIN
19-1/4”
1/2”
VENTED CHASE: COMBUSTIBLE OVER FACE OF
APPLIANCE IS ALLOWED.
28