KC-351S POWER SUPPLY (220V-1 PHASE)
WARNING:
YOUR KC-351S (220V) MUST BE CONNECTED TO A
220V, 20-AMP, BRANCH CIRCUIT. FAILURE TO CONNECT IN THIS
WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.
220V OPERATION
As received from the factory, your shaper is wired for 220V operation.
This shaper is intended for use on a circuit that has an outlet and a
plug which looks like the one illustrated in Fig.2. (220V Plug not
included).
GROUNDING
This shaper must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current, to
reduce the risk of electric shock. This shaper must be equipped with
a cord having an equipment-grounding conductor and grounding
plug. The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local codes
and ordinances.
Not all outlets are properly grounded. If you are not sure if your
outlet is properly grounded, have it checked by a qualified electrician.
WARNING:
IF NOT PROPERLY GROUNDED, THIS SHAPER CAN
CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN
DAMP LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER
CORD IS WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.
WARNING:
TO MAINTAIN PROPER GROUNDING OF YOUR
SHAPER, DO NOT REMOVE OR ALTER THE GROUNDING PRONG
IN ANY MANNER.
WARNING:
DO NOT USE A TWO-PRONG ADAPTOR FOR THEY
ARE NOT IN ACCORDANCE WITH LOCAL CODES AND
ORDINANCES. NEVER USE IN CANADA.
220V Plug
A 220V plug is not supplied with this shaper and must be purchased at
your local hardware store. The 220V plug must be a CSA listed plug
suitable for 220V operation. This plug is illustrated in Fig.2. Contact
your authorized service center or qualified electrician to install the plug.
The shaper must comply with all local and national codes after the
220V plug is installed.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the
following table to determine the minimum wire size (A.W.G-American
Wire Gauge) extension cord. Use only extension cords which accept
the tool’s plug.
For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample
voltage to the motor. Refer to Fig.3 for wire length and size.
ELECTRICAL INFORMATION &
SPECIFICATIONS
WARNING!
ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE MACHINE DISCONNECTED FROM THE POWER
SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
FIGURE 2
PROPERLY GROUNDED OUTLET
CURRENT CARRYING PRONGS
GROUNDING PRONG
SHAPER SPECIFICATIONS
MODEL
KC-351S
Dimensions (LxWxH)
31” x 30” x 46”
Spindle speed
8,000 & 10,000 RPM
Table height
34”
Motor
15 Amp.
Voltage
220V, 1 phase, 60 Hz
Weight
342 Lbs.
Spindle diameter
1/2”, 3/4”
Table size
28” x 30”
Spindle openings on table
1 5/8”, 3”, 3-1/2”, 7”
Spindle length
(1/2”) 4”, (3/4”) 4-5/8”
Spindle Travel
3”
LENGTH OF
CONDUCTOR
0-50 FEET
51-100 FEET
OVER 100 FEET
WIRE SIZES REQUIRED
(AMERICAN WIRE GAUGE)
220V LINES
NO.14
NO.12
Not Recommended
FIGURE 3
Under nut capacity
(1/2”) 3”, (3/4”) 3”
Dust chute diameter
4”