1- PRODUCT DESCRIPTION
!
The control unit has been designed to manage 1 or 2 230 Vac motors gate automations.
To start the system it is necessary to:
1- Connect the power supply, the motors, and the accessories as indicated in the 2nd paragraph
2- Set the dip-switches (paragraph 4A) and the trimmers (paragraph 4B) depending on the wanted functioning and on the
conditions of the system.
3- Perform the standard programming procedure (paragraph 6B) or the professional programming procedure (paragraph 6D), to
recognize the starting point and the end point of the travel.
4- Perform the checks reported on paragraph 6C (warning before starting).
If the control unit keeps on having problems after these steps, see paragraph 9 “Signaling led”, to identify possible
anomalies, and paragraph 14 “inconvenient and remedy” to try to eliminate them.
1B - STARTING MODALITY
- Management and control for 1 or 2 230Vac motors (terminals 30,31,32,33,34,35).
- Double opening-closing limit switch inputs (terminals 4,5,6,7,8).
- 433.920Mhz rolling code built-in receiver (code: “RX STAR”, see paragraph 1A – 13B).
- Removable memory (code: “MEMO 200”) containing up to 200 memorized radio codes (paragraph 1A - 13A).
- 6 signaling led (paragraph 1A – 9).
- Predisposition for the card for electric lock control connection (max 15W, optional) (see paragraph 12D).
- Customizable and differentiable slow down in opening and closing thanks to the professional learning procedure (see paragraph 6D).
- Built-in lamp intermittent manager (see paragraph 12A).
- Customizable pedestrian opening by pedestrian programming procedure (see paragraph 7).
- Customizable delay between the wings in closing from 0 to 15 sec. by trimmer (see paragraph 4B).
- Pause time before automatic reclosing customizable from 0 to 90 sec. by trimmer (see paragraph 4B).
- Sensibility of the intervention adjustable from 0.1 to 3 sec. by trimmer (see paragraph 4B).
- Power/speed adjustable from 50% to 100% by trimmer (see paragraph 4B).
- Input for control-by-wire to manage start, stop and pedestrian opening.
- Double safety inputs: closing (terminal 13) and opening and closing (terminal 14).
- Input for warning light to signal the wings position (see paragraph 12C).
1C - MAIN FEATURES
If you perform the standard programming procedure (see paragraph 6B), and there are no modifications on the trimmer regula-
tion (see paragraph 4B) and on dip switches (see paragraph 4A), the control unit will act as follows:
- The safety devices in closing, connected to “PHO1” contact (terminal 13), will intervene only in closing, inverting the motion.
- The safety devices in opening, connected to “PHO2” contact (terminal 14),
will intervene both in closing and in opening,
keeping on the motion when the device has been cleared (setting by the dip 5 “PHO2”).
- Activation of electric limit switches management (terminals 4,5,6,7,8) only if they are connected. If there are no electric limit
switches, the terminals must be free.
- Pause time before automatic reclosing equal to 45 seconds.
- Pedestrian opening procedure controlled by cable and by transmittter (if the transmitter has been programmed by the
procedure as per paragraph 3b) and with total wing opening operated by MOT1 (terminals 30,31,32).
- The slowdowns are set to the final 15% of the travel.
1E - PRESETS
1A - GENERAL DESCRIPTION
Signaling led
(Paragraph 9)
Programming
buttons
Dip-switch function
setting
(Paragraph 4A-5)
Setting trimmers
(Paragraph 4b-8)
Removable
spare fuse
Control unit supply
230 Vac
Secondary 1 transformer
12 Vac
Primary transformer
230 Vac
Secondary 2 transformer
20 Vac
24 Vdc, max 15W, protected by fuse
Photocells output
230 Vac, max 25W, protected by fuse
Flashing lamp output (Terminals 28,29)
24 Vdc, max 3W, protected by fuse
Open gate warning light output (Terminals 15,17)
-20 ÷ +55
Working temperature
20Va
Transformer power
Motor output
230 Vac (Maximum 500Watt per motor)
1D - TECHNICAL DATA