background image

Use the “

FOR” trimmer to adjust the voltage with which the motor is powered during operation, thus adjusting its speed. This is 

settable between 50% and 100% of the maximum force and can be increased by turning the trimmer clockwise. Thus if the 

trimmer is set on the minimum then the speed is equal to about 50%, if adjusted in an intermediate position it is equal to 75%, 

while at the maximum the speed will be the largest obtainable.  
     A variation of the “FOR” trimmer requires the repetition of the learning procedure since the operation times, and 

thus the moments in which to start the slow-down, vary. 

8 - TRIMMER 

9 - LED 

8A - Trimmer “FOR” – Power / speed of the motor 

The “

PAU” trimmer is used to set the pause time of the control unit if the automatic closing is enabled by means of DIP 6 

“AUTO”. The pause time is settable between 3 and 90 seconds and can be increased by turning the trimmer clockwise. Thus if 

the trimmer is set at the minimum then the pause time is equal to about 3 seconds, if adjusted to an intermediate position it is 

equal to about 28 seconds, while at the maximum the pause time will be about 90 seconds.

8B - Trimmer “PAU” - Pause time 

The “

DEL” trimmer is used to adjust the delay between the start of the motors both in opening and in closing. If the trimmer is set 

at the minimum, there is no delay, and the wings will open and close simultaneously. In the other positions, the delay in opening 

is set to 3 seconds, and the delay in closing can be set between 0 and 15 seconds, depending on the trimmer position.  

8B - Trimmer “DEL” – Delay between the wings 

The “

OBS” trimmer is used to adjust both the intervention delay after detection of an obstruction and the opposing force to be 

used by the automation. This function is useful to overcome any critical points of the automation where, for a brief time interval, 

there is greater power absorption by the motor. Both the intervention delay and the opposing force can be increased by turning 

the trimmer clockwise. The intervention delay can be set between 0.1 and 3 seconds. Thus if the trimmer is set at the minimum 

then the intervention time is equal to about 0.1 seconds, if adjusted to an intermediate position it is equal to about 1.5 seconds, 

while at the maximum the intervention time will be about 3 seconds. See also paragraph 11D. 

8C - Trimmer “OBS” - Obstacle sensitivity 

YELLOW LED “SET”: 

- flashes for 5 seconds when turned on to indicate that it is possible to enter the professional, simplified, or pedestrian learning modes

- lights up with a fixed light while professional or simplified learning are carried out.

- is switched off when the control unit functions normally

RED LED “RAD”:

- flashes briefly when a 433 MHz Multipass radio code is received

- is fixed on when radio codes are being memorized

- flashes rapidly when the control unit is switched on and the radio code memory is defective

- flashes rapidly during the cancellation of radio codes

- flashes slowly in case of attempt to insert codes with the memory full

- is switched off when the control unit is functioning normally and waiting to receive a command via radio.

RED LED “PH”: 

-is switched on when the photocell is properly installed

-is switched off when the photocell does not work (interrupted or not aligned)

GREEN LED “START” 

–is switched on when the step-by-step contact (STR) is closed (the control unit receives the signal)

- is switched off when the step-by-step contact (STR) is opened (the control unit does not receive the signal)

RED LED “ST”:

- is switched on when the STOP input (STP) is closed

- is switched off when the STOP input (STOP) is opened

RED LED “ER”: 

- is switched off when the control unit functions normally

- is switched on in case of failure of safety test (see paragraph 11C)

- is switched on in case of anomalies on the control unit (try to program the control unit again)

The leds show the state of the control unit and of some of the connected accessories. Normally, when the control unit is 

powered and working, the red PH led and the red ST led should be on. Otherwise, verify the connected accessories, or the 

bridges which substitute them. 

9A - WARNING LED 

The pedestrian opening is a partial opening (or total opening, if the installer wants it) of the wing opened by “

MOT1” (terminals 

30,31,32). To manage the pedestrian opening, it is necessary to program a button of the radio transmitter (see paragraph 3B), 

or connect a command by wire on the terminals 10,12(see paragraph 10B).

The installer can set the pedestrian opening through this procedure. 

7. The gate stops and recloses. 

END of the learning procedure. 

1. Place the wings in  

closing position. 

2. RESET: press

button 

SET for

2 seconds (the yellow 

led flashes).

3. Press 

START  

button  

(the yellow led stays on). 

4. Within 5 seconds, press a 

command by wire, the  

START button, or a button 

in the transmitter. 

5. The gate begins to open. 

6. Press the command by 

wire, the 

START button, or  

the button in the transmitter, 

to set the widening of the 

pedestrian opening 

1. Place the wings in  

closing position. 

2. RESET: press button SET 

for 

2 seconds (the yellow led 

flashes).

3. Press 

START button 

(the yellow led stays on). 

4. Press button 

SET

(the yellow led flashes 

quickly).

5. END of deletion. The  

yellow led turns off. 

7 - PARTIAL OPENING LEARNING PROCEDURE 

7A - LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING 

The installer can delete the pedestrian opening procedure through this procedure. 

After the deletion, it will be possible to activate the pedestrian opening only by wire, and the size of the opening will 

be total on the wing opened by MOT1

7B - DELETING THE PEDESTRIAN OPENING 

Summary of Contents for Star 2230

Page 1: ...Star 2230 INSTRUCTION MANUAL EN Star 2230 Control unit for 1 or 2 230Vac motors ...

Page 2: ...1 PRODUCT DESCRIPTION 1A GENERAL DESCRIPTION Signaling led Paragraph 9 Programming buttons Dip switch function setting Paragraph 4A 5 Setting trimmers Paragraph 4b 8 Removable spare fuse ...

Page 3: ... by trimmer see paragraph 4B Sensibility of the intervention adjustable from 0 1 to 3 sec by trimmer see paragraph 4B Power speed adjustable from 50 to 100 by trimmer see paragraph 4B Input for control by wire to manage start stop and pedestrian opening Double safety inputs closing terminal 13 and opening and closing terminal 14 Input for warning light to signal the wings position see paragraph 12...

Page 4: ...inals 4 6 7 8 common limit switches 7 Opening limit switch motor 2 8 Closing limit switch motor 2 9 START contact 10 Terminal 9 11 12 COMMON 11 STOP contact 12 Pedestrian opening contact PED 13 Safety devices in closing contact PHO1 14 Safety devices in opening contact PHO2 15 Terminals 16 and 17 COMMON 0V 16 PHOTOCELLS 24Vdc 17 WARNING LIGHT 24Vdc max 3W 18 Electric lock control negative positive...

Page 5: ...to be free not bridged The control unit activate the contact only if it receive signals from connected contacts If there are no connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed input PHO2 and or terminal 11 STOP the concerning inputs must be bridged If there are connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed in...

Page 6: ...inals 4 6 7 8 common limit switches 7 Opening limit switch motor 2 8 Closing limit switch motor 2 9 START contact 10 Terminal 9 11 12 COMMON 11 STOP contact 12 Pedestrian opening contact PED 13 Safety devices in closing contact PHO1 14 Safety devices in opening contact PHO2 15 Terminals 16 and 17 COMMON 0V 16 PHOTOCELLS 24Vdc 17 WARNING LIGHT 24Vdc max 3W 18 Electric lock control negative positive...

Page 7: ...to be free not bridged The control unit activate the contact only if it receive signals from connected contacts If there are no connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed input PHO2 and or terminal 11 STOP the concerning inputs must be bridged If there are connected devices on the terminal 13 normally closed input PHO1 terminal 14 normally closed in...

Page 8: ... the setting of FOR trimmer power speed requires the repetition of the learning procedure point 2 because of the change of the manoeuvre time The slowdowns are automatically set in the last 15 of the travel 4B TRIMMER SETTINGS 4A DIP SWITCHES SETTINGS DIP 1 ON OFF ON OFF ON OFF FAST 2 STRIKE 3 LAMP ON OFF 4 PHO2 ON OFF 5 AUTO ON OFF 6 STEP ON OFF 7 SLOW ON OFF 8 RADIO DIP STATUS FUNCTIONING DESCRI...

Page 9: ...ocell If the PHO2 dip switch is set to OFF the safety devices in opening when they intervene invert the motion for 2 seconds and then they stop the automation So it is necessary to supply a command by wire or by transmitter to finish the travel and close the wings typical functioning of the safety edge With this setting these safety devices in closing do not intervene 5E DIP SWITCH 5 PHO2 see also...

Page 10: ...he programming procedure verify that The motors shut down a few seconds after the end of the programming procedure The control unit respond to the inputs received by wire START terminal 9 pedestrian opening terminal 12 and STOP terminal 11 The control unit respond to the inputs received by transmitter The safety devices connected to PHO1 terminal 13 intervene while the gate is closing and prevent ...

Page 11: ...mote control for the second wing 12a Choose the point of slow down with the button SET or the button 1 of the transmitter for the first wing and with the button RADIO or the button 2 of the remote control for the second wing 7 Push SET button or a button of the radio transmitter The control unit performs the opening END of learning yellow led turns off 5 The control unit perform a little opening c...

Page 12: ... a command by wire the START button or a button in the transmitter 5 The gate begins to open 6 Press the command by wire the START button or the button in the transmitter to set the widening of the pedestrian opening 1 Place the wings in closing position 2 RESET press button SET for 2 seconds the yellow led flashes 3 Press START button the yellow led stays on 4 Press button SET the yellow led flas...

Page 13: ...turning the trimmer clockwise The intervention delay can be set between 0 1 and 3 seconds Thus if the trimmer is set at the minimum then the intervention time is equal to about 0 1 seconds if adjusted to an intermediate position it is equal to about 1 5 seconds while at the maximum the intervention time will be about 3 seconds See also paragraph 11D 8C Trimmer OBS Obstacle sensitivity YELLOW LED S...

Page 14: ...closing commands neither automatic nor by wire as long as the contact will be opened again The pedestrian opening is a partial opening or total opening if the installer wants it of the wing opened by MOT1 terminals 30 31 32 To activate the pedestrian opening function it is necessary to make the pedestrian opening programming procedure see paragraph 7 The pedestrian opening can be managed by a chan...

Page 15: ...e the motors absorb more current 11D OBSTACLE DETECTION BY POWER ABSORPTION The control unit has a self test function of the safeties connected to the PHO1 and PHO2 input It switches off the transmitter to check the commutation of the corresponding receiver contact before the execution of each manoeuvre To activate this self test function proceed as follows connect the positive of the photocell tr...

Page 16: ...King Gates S r l Via A Malignani 42 33077 Sacile PN ITALY Tel 39 0434 737082 Fax 39 0434 786031 e mail info king gates com web www king gates com MADE IN ITALY ...

Reviews: