2.11
FITTING THE TERMINAL GUARD
With the flue terminal in position, place the terminal guard over the top of the flue
terminal and mark the position of the holes on the outer wall. Remove the terminal
guard and drill the 4 off 6 mm holes. Insert the raw plugs into the drilled holes,
replace the terminal guard over the top of the flue terminal and attach to the wall
using the No.12 x 40mm screws provided with the terminal guard. See Fig. 23
below.
Fig. 23
NOTE : In England & Wales, the building regulations require that a terminal
guard should be fitted if the terminal could come into contact with people
near the building or be subject to damage. BFM Europe Ltd. also
recommend the fitting of a flue terminal guard where regulations do not
demand that it be fitted. A suitable flue terminal guard is supplied with the
appliance.
19