In instances where a large depth cavity wall, chimney breast is encountered, or if
the installation requires a flue termination to the left or right hand of the
combustion chamber, the overall length from the centre of the flue spigot can be
increased up to 1600mm as shown below in Fig. 14
Fig. 14
In installation’s where components are required that exceed the limitations of the
components supplied with the standard kit, extra lengths of flue pipe are available
from BFM Europe Ltd. The lengths available and part no’s are shown below.
B-83970
1000mm Flue Length Section
B-83980
500mm Flue Length Section
B-83990
250mm Flue Length Section
B-84000
150mm Flue Length Section
Always ensure that the solid section is fitted to the elbow when installing
extra sections, followed by the telescopic section as supplied in the
standard flue kit, this will allow for differences in cavity wall depth to be
allowed for. See Fig. 15 overpage
13
1600mm Maximum
1600mm Maximum
1600mm
Maximum
Combustion Chamber
2000mm
Maximum