PREPARATION OF THE WALL / MOUNTING
The appliance and flue pipes must be installed at right angles to the mounting
wall. The appliance itself should be installed vertically against a flat wall. Where
an uneven wall surface is found, appropriate action should be taken to ensure that
the appliance is not stressed or does not distort when installed.
Ensure that the floor surface onto which the appliance is mounted onto is flat.
The minimum height from the mounting base to the centre of the flue is shown on
below in Fig. 16.
NOTE
: Adjustable feet are fitted to the combustion chamber to allow fine tuning of
it’s positioning
Fig. 16
14
Additional Flue
Length e.g. 1000mm to
be fitted onto elbow
before telescopic
section is fitted, to take
into account
variation in wall cavity
depths
250mm to
410mm
Telescopic
Section
90 degree
elbow
150mm Starter Pipe
Flue
Terminal
Combustion
Chamber
900mm to
CRS of
Flue Pipe
Elbow
150mm Starter Pipe
A minimum clearance of
100mm is required above the
top of the flue pipe to
combustible surfaces