5.5
OPERATING THE FIRE - ELECTRONIC FIRE CONTROL
MODELS.
5.5.1
To light the fire using the EFC switch press and hold the power button
continuously until the red light illuminates next to the operation symbol
(this typically takes two seconds). As the red light illuminates release
immediately the power button. While the burner is lighting the red light
will flash. When the burner has lit the red light will stop completely.
The burner will now be lit at maximum heat input level.
NOTE : If the power button is pressed for too long or two short a time,
the lighting sequence will be interrupted and not complete. The reason
for the EFC switch having this strict start sequence is for safety reasons
so that the starting operation of the fire will be most unlikely to be
done other than intentionally by an adult.
Fig. 2
5.5.2
To decrease the heat input level of the fire’s burner, pressing and
releasing the - button will lower the heat input level one step at a time.
Pressing the - button continuously will move the heat input level to the
minimum. There is also a flame adjuster which is located on the burner
unit control panel which slides from left to right. The left hand position
gives maximum efficiency and output whereas the right hand position
gives more flame but slightly less radiant glow.
52
Operation symbol
(illuminates red)
- button (decreases
heat input level)
+ button (increases
heat input level)
Power button