6
DIGITAL AUTO RANGING MULTIMETER
AC Current
Range
Resolution
Accuracy
400µA
0.1µA
± (1.0% of rdg + 5dgts)
4000µA
1µA
40mA
10µA
400mA
100µA
4A
1mA
± (1.5% of rdg + 7dgts)
10A
10mA
Caution: For measurements greater than 5A, 10 seconds is the maximum probing time.
You must wait 15 minutes before reusing the multimeter.
Overload Protection:
“mA” jack: F0.5A/600V Fuse
“10A” jack: F10A/600V Fuse
Max Input Current:
“mA” jack: 400mA
“10A” jack: 10A
Voltage Drop: 400µA, 40mA and 4A ranges: 20mV
4000µA, 400mA and 10A Ranges: 200mV
Frequency Range: 40Hz ~ 400Hz
Resistance (Auto Ranging)
Range
Resolution
Accuracy
400
Ω
0.1
Ω
± (1.5% of rdg + 3dgts)
4K
Ω
1
Ω
40K
Ω
10
Ω
400K
Ω
100
Ω
4M
Ω
1K
Ω
40M
Ω
10K
Ω
Open Circuit Voltage: about 0.25V
Overload Protection: 250V DC/AC rms