DIGITAL AUTO RANGING MULTIMETER

AC Voltage (Auto Ranging)

Range

Resolution

Accuracy

400mV

0.1mV

± (1.2% of rdg + 5dgts)

4V

1mV

± (1.2% of rdg + 3dgts)

40V

10mV

400V

100mV

600V

1V

± (1.2% of rdg + 8dgts)

Input Impedance: 10MΩ

Frequency Range: 40Hz~400Hz

Maximum Input Voltage: 600V DC/AC rms

Max Input Voltage: 600V AC rms

Transistor hFE Test

Range

hFE

Test Current

Test Voltage

PNP & NPN

0 ~ 1000

lb≈2µA

Vce≈1V

DC Current

Range

Resolution

Accuracy

400µA

0.1µA

± (0.8% of rdg + 5dgts)

4000µA

1µA

40mA

10µA

400mA

100µA

4A

1mA

± (1.5% of rdg + 3dgts)

10A

10mA

Caution: For measurements greater than 5A, 10 seconds is the maximum probing time. 
You must wait 15 minutes before reusing the multimeter. 

Overload Protection: 

  “mA” jack: F0.5A/600V Fuse

  “10A” jack: F10A/600V Fuse

Max Input Current:

  “mA” jack: 400mA

  “10A” jack: 10A

Voltage Drop: 400µA, 40mA and 4A ranges: 20mV

   

        4000µA, 400mA and 10A Ranges: 200mV

Summary of Contents for K8315

Page 1: ...AUTO RANGING DIGITAL MULTIMETER K8315 ED1 May 17 LARGE DIGITAL DISPLAY 12 MONTH WARRANTY AC DC VOLTAGE CURRENT MEASUREMENT CAT II SAFETY RATING CAT III TEST LEAD SAFETY RATING...

Page 2: ...ct or 9 DATA H Button Hold 10 Test Leads CAT III 11 Multi Function Capacitance Transistor Adaptor Model No K8315 Analog Display 42 segments updates 12 5 times sec Digital Display 3999 Counts updates 2...

Page 3: ...before using the Meter e Verify the Meter s operation by measuring a known voltage before and after using it Do not use the Meter if it operates abnormally Protection may be impaired If in doubt have...

Page 4: ...tion Wear approved safety eye protection 3 Service a Tool service must be performed only by qualified repair personnel b When servicing a tool use only identical replacement parts Use only authorized...

Page 5: ...nd Low Battery Fuse Diode Continuity Test Conforms to European Union Directive Double Insulated 6 Multimeters Function Table Model DCV ACV DCA ACA hFE CAP Hz K8315 8 Multimeter Product Specifications...

Page 6: ...ge hFE Test Current Test Voltage PNP NPN 0 1000 lb 2 A Vce 1V DC Current Range Resolution Accuracy 400 A 0 1 A 0 8 of rdg 5dgts 4000 A 1 A 40mA 10 A 400mA 100 A 4A 1mA 1 5 of rdg 3dgts 10A 10mA Cautio...

Page 7: ...u must wait 15 minutes before reusing the multimeter Overload Protection mA jack F0 5A 600V Fuse 10A jack F10A 600V Fuse Max Input Current mA jack 400mA 10A jack 10A Voltage Drop 400 A 40mA and 4A ran...

Page 8: ...nt do not attempt to take any voltage measurements which may exceed 600V DC or 600V AC rms Do not apply more than 600V DC or 600V AC rms between the common terminals and the earth ground 1 Connect the...

Page 9: ...high voltage capacitors before measuring resistance 1 Connect the BLACK test lead 10 to the COM jack 6 and RED lead 10 to the V jack 7 Note The polarity of the RED test lead 10 is positive 1 Set the...

Page 10: ...he COM Jack 6 and the mA jack 5 Ensure the writing on the Multi Function Capacitance Transistor 11 is correctly orientated Identify whether the transistor is NPN or PNP type and locate Emitter base an...

Page 11: ...Tel 1300 657 528 The applicable warranty period 12 months commences on the date that the product is purchased If this product has materials or workmanship defects other than defects caused by abnorma...

Page 12: ...11 DIGITAL AUTO RANGING MULTIMETER Notes...

Page 13: ...www kincrome com au...

Reviews: