Constant-Power (CP) Mode
In constant-power (CP) mode, the current flow is controlled to maintain constant
power dissipation in the load.
The PCZ1000A operates as a constant-power load, as shown in Fig.A-8 load within
the range shown in Fig.A-1. If the RMS input voltage increases, the PCZ1000A
reduces the RMS current flow accordingly to keep the apparent power (P= V x I)
constant. In Fig.A-8, P = V2 x I2 = V3 x I3.
Fig.A-8
CP Mode
rms value of the input
current I
rms value of the input
voltage V
0
V3
V2
I3
I2
Constant-power